16.1.3 How to Replace the Vacuum Pump Oil
The oil in the vacuum pump must be replaced when you are prompted to do so by the
device.
You must carefully read and understand this Operating Manual to perform the
provided instructions correctly.
a)
Vacuum pump
b)
Filler cap
c)
Ground terminal
d)
Oil drain cap
Proceed as follows:
1. Disconnect the device from the power mains.
2. Unscrew the oil drain cap.
3. Wait for all the oil to drain from the pump.
Collect the recovered oil and dispose of it according to the
regulations in force.
4. Screw the oil drain cap on.
5. Unscrew the oil filler cap.
6. Fill with new oil.
The correct pump oil level is approximately half of the level sight and
the total amount to refill is approximately: 42 cl / 12.5 oz.
7. Screw the oil filler cap on.
8. Switch on the equipment.
9. Select: ADDITIONAL FUNCTIONS -> RESET COUNTERS -> TOTAL PUMP TIME
10. Follow the instructions in the display.
For more information see the software's Operating Manual.