16.1.1 Dehydrator Filter Replacement
The filter must be replaced when you are prompted to do so by the device.
There could be accidental refrigerant leaks while replacing the
filter.
Carefully follow the instructions provided below to avoid the
refrigerant from getting into the atmosphere.
Wear appropriate protective glasses and gloves while replacing
the filter.
You must carefully read and understand this Operating Manual
to perform the provided instructions correctly.
Before replacing the filter you must reset the "filter counter" using the appropriate software
function.
Proceed as follows:
1.
Switch on the equipment.
2.
Select: ADDITIONAL FUNCTIONS -> RESET COUNTERS -> SOSTITUZIONE FILTRO
3.
Follow the instructions on the display.
Do not open the equipment's service door until it is specifically
indicated on the display.
After resetting the counter you can replace the filter.
a)
Screw nuts for the filter
b)
Blocking clip
c)
Filter
d)
Arrow indicating the direction of the flow
43