Publication date: Jan, 2009
Revision A1
204
Example:
ES-2410C (gvrp)# set restricted 1-10 enable
ES-2410C (gvrp)# show config
GVRP state: Enable
Port Join Time Leave Time LeaveAll Time Applicant Registrar Restricted
---- --------- ---------- ------------- --------------- --------- ----------
1 20 60 1000 Normal Normal Enable
2 20 60 1000 Normal Normal Enable
3 20 60 1000 Normal Normal Enable
4 20 60 1000 Normal Normal Enable
5 20 60 1000 Normal Normal Enable
6 20 60 1000 Normal Normal Enable
7 20 60 1000 Normal Normal Enable
8 20 60 1000 Normal Normal Enable
9 20 60 1000 Normal Normal Enable
10 20 60 1000 Normal Normal Enable
:
:
22 20 60 1000 Normal Normal Disable
23 20 60 1000 Normal Normal Disable
24 20 60 1000 Normal Normal Disable
25 20 60 1000 Normal Normal Disable
26 20 60 1000 Normal Normal
Disable
set timer
Syntax:
set timer <range> <join> <leave> < leaveall >
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
<range> : port range, syntax 1,5-7, available from 1 to 26
<join>: join timer, available from 20 to 100
<leave>: leave timer, available from 60 to 300
<leaveall>: leaveall timer, available from 1000 to 5000
Leave Time must equal double Join Time at least.
Possible value:
<range> : 1 to 26
<join>: 20 to 100
<leave>: 60 to 300
<leaveall>: 1000 to 5000
Example:
ES-2410C (gvrp)# set timer 2-8 25 80 2000