Display Group (continued)
Sailer Manual HPVFE
38
d018 [Elapsed Run Time]
Accumulated time drive is outputting power. Time is displayed in 10-hour increments.
Values
Default
Read Only
Min/Max:
0/9999 Hrs
Display:
1 (= 10 Hrs)
d019 [Testpoint Data]
Related Parameter(s): A459
The present value of the function selected in A459 [Testpoint Sel].
Values
Default
Read Only
Min/Max:
0/FFFF
Display:
1 Hex
d020 [Analog In 0-10V]
Related Parameter(s): t211, t212
The present value of the voltage at I/O Terminal 13 (100.0% = 10 volts).
Values
Default
Read Only
Min/Max:
0.0/100.0%
Display:
0.1%
d021 [Analog In 4-20mA]
Related Parameter(s): t213, t214
The present value of the current at I/O Terminal 15 (0.0% = 4mA, 100.0% = 20mA).
Values
Default
Read Only
Min/Max:
0.0/100.0%
Display:
0.1%
d022 [Drive Temp]
Present operating temperature of the drive power section.
Values
Default
Read Only
Min/Max:
0/120 degC
Display:
1 degC