EasyManua.ls Logo

Saftronics HPVFE - Elapsed Time and Testpoint Data; Elapsed Run Time Display (d018); Testpoint Data Display (d019); Analog Input Value Display

Saftronics HPVFE
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Display Group (continued)
Sailer Manual HPVFE
38
d018 [Elapsed Run Time]
Accumulated time drive is outputting power. Time is displayed in 10-hour increments.
Values
Default
Read Only
Min/Max:
0/9999 Hrs
Display:
1 (= 10 Hrs)
d019 [Testpoint Data]
Related Parameter(s): A459
The present value of the function selected in A459 [Testpoint Sel].
Values
Default
Read Only
Min/Max:
0/FFFF
Display:
1 Hex
d020 [Analog In 0-10V]
Related Parameter(s): t211, t212
The present value of the voltage at I/O Terminal 13 (100.0% = 10 volts).
Values
Default
Read Only
Min/Max:
0.0/100.0%
Display:
0.1%
d021 [Analog In 4-20mA]
Related Parameter(s): t213, t214
The present value of the current at I/O Terminal 15 (0.0% = 4mA, 100.0% = 20mA).
Values
Default
Read Only
Min/Max:
0.0/100.0%
Display:
0.1%
d022 [Drive Temp]
Present operating temperature of the drive power section.
Values
Default
Read Only
Min/Max:
0/120 degC
Display:
1 degC

Related product manuals