64
Chapter 4 Troubleshooting
Chapter 4 provides information to guide you in troubleshooting the HPVFE drive. Included is a listing and
description of drive faults (with possible solutions, when applicable).
For information on…
See page
For information on…
See page
Drive Status
4-1
Fault Descriptions
4-3
Faults
4-1
Common Symptoms and
Corrective Actions
4-5
Drive Status
The condition or state of your drive is constantly monitored. Any changes will be indicated through the integral
keypad.
LED Indications
See
page 2-3
for information on drive status indicators and controls.
Faults
A fault is a condition that stops the drive. There are two fault types.
Type
Fault Description
Auto-Reset/Run
When this type of fault occurs, and A451 [Auto Rstrt Tries] is set to a value greater than “0,” a user-
configurable timer, A452 [Auto Rstrt Delay], begins. When the timer reaches zero, the drive
attempts to automatically reset the fault. If the condition that caused the fault is no longer present,
the fault will be reset and the drive will be restarted.
Non-Resetable
This type of fault may require drive or motor repair, or is caused by wiring or programing errors.
The cause of the fault must be corrected before the fault can be cleared.