EasyManuals Logo

Saftronics HPVFE User Manual

Saftronics HPVFE
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Basic Program Group (continued)
Sailer Manual HPVFE
43
P110 [Decel Time 1]
Related Parameter(s): P108, P109, t201, t202, A402, A410-A413
Sets the rate of deceleration for all speed decreases.
Maximum Freq/Decel Time
=
Decel Rate
Values
Default
10.0 Secs
Min/Max:
0.1/600.0 Secs
Display:
0.1 Secs
P111 [Motor OL Ret]
Related Parameter(s): P103
Enables/disables the Motor Overload Retention function. When Enabled, the value held in the motor overload counter is saved at power-down
and restored at power-up. A change to this parameter setting resets the counter.
Options
0
“Disabled” (Default)
10.0 Secs
1
“Enabled”
0.1 Secs
P112 [Reset To Defalts]
Stop drive before changing this parameter.
Resets all parameter values to factory defaults.
Options
0
“Idle State” (Default)
1
“Reset Defaults”
After the reset function is complete, this parameter will set itself back to “0”.
Causes an F48 Params Defaulted fault.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Saftronics HPVFE and is the answer not in the manual?

Saftronics HPVFE Specifications

General IconGeneral
BrandSaftronics
ModelHPVFE
CategoryDC Drives
LanguageEnglish

Related product manuals