Basic Program Group (continued)
Sailer Manual HPVFE
43
P110 [Decel Time 1]
Related Parameter(s): P108, P109, t201, t202, A402, A410-A413
Sets the rate of deceleration for all speed decreases.
Maximum Freq/Decel Time
=
Decel Rate
Values
Default
10.0 Secs
Min/Max:
0.1/600.0 Secs
Display:
0.1 Secs
P111 [Motor OL Ret]
Related Parameter(s): P103
Enables/disables the Motor Overload Retention function. When Enabled, the value held in the motor overload counter is saved at power-down
and restored at power-up. A change to this parameter setting resets the counter.
Options
0
“Disabled” (Default)
10.0 Secs
1
“Enabled”
0.1 Secs
P112 [Reset To Defalts]
Stop drive before changing this parameter.
Resets all parameter values to factory defaults.
Options
0
“Idle State” (Default)
1
“Reset Defaults”
After the reset function is complete, this parameter will set itself back to “0”.
Causes an F48 Params Defaulted fault.