VM1000B
- 28 -
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
23: PLC status reset
24: Swing pause
25: Counter input
26: Counter reset
27: Length count input
28: Length reset
29: Torque control prohibited
30: Pulse input (only valid for DI6)
31: Reserved
32: Immediate dc braking
33: External faults often closed input
34:frequency setting effect terminal (this
terminal function is not set, the default is valid)
35: Reverse PID action direction
36: External stop terminal 1
37: Command source switchover terminal 1
38: PID integral pause
39: Frequency source X and preset
frequency
switchover terminals
40: Frequency source Y and preset
frequency
switchover terminals
41 42: Reserved
43: PID parameter switchover terminal
44: User-defined fault 1
45: User-defined fault 2
46: Speed control/torque control
switchover
47: Emergency stop
48: External stopping terminal 22
49: Deceleration dc braking
50: Clear the current running time
51: Timing enable
52: Timed reset
5359: Reserved
F5.15
DI filter time
0.000s 1.000s
0.010s
050F
F5.16
Terminal command mode
0: Two-line mode 1
1: Two-line mode 2
2: Three-line mode 1
3: Three-line mode 2
0
0510
F5.17
UP/DOWN change rate
range
0.01Hz 6553.5Hz
0.50Hz
0511
F5.18
AI1 minimum input
0.00V F5.20
0.00V
0512
F5.19
Percentage rate of AI1
minimum input
-100.0% +100.0%
0.00%
0513
F5.20
AI1 maximum input
F5.18 +10.00V
10.00V
0514
F5.21
Percentage rate of AI1
maximum input
-100.0% +100.0%
100.00%
0515