4.1 Function Code
F1 Group - Auxiliary Operating Parameters
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
F1.19 Acc/Dec time unit 0: second 1: minute 2: 0.1s 1 0
F1.20
Frequency setting of
forward jog operation
0.00 ~【F0.16】upper limit
frequency
0.01Hz 5.00
F1.21
Frequency setting of
reverse jog operation
0.00 ~【F0.16】upper limit
frequency
0.01Hz 5.00
F1.22 Jog Acc time
0.1 ~ 3600.0s
0.4 ~ 4.0KW 7.5s
5.5 ~ 30.0KW 15.0s
37.0 ~ 132.0KW 40.0s
160.0 ~ 630.0KW 60.0s
0.1s
Depending
on model
F1.23 Jog Dec time 0.1s
Depending
on model
F1.24 Jog interval time 0.0 100.0s 0.1s 0.1
F1.25 Hopping freq.1 0.00 upper limit freq. 0.01Hz 0.00
F1.26 Hopping freq.1 range 0.00 upper limit freq. 0.01Hz 0.00
F1.27 Hopping freq.2 0.00 upper limit freq. 0.01Hz 0.00
F1.28 Hopping freq.2 range 0.00 upper limit freq. 0.01Hz 0.00
F1.29 Hopping freq.3 0.00 upper limit freq. 0.01Hz 0.00
F1.30 Hopping freq.3 range 0.00 upper limit freq. 0.01Hz 0.00
F1.31
Action when set freq. is
lower than lower limit
freq.
0: run at lower limit freq.
1: run at zero freq. after delay
time (start without delay)
2: stop after delay time (start
without delay)
1 0 ×
F1.32
Delay time of stopping
when freq. is lower
than limit (simple
sleep)
0.0 3600.0s 0.1s 10.0
F1.33
Zero freq. brake
current
0.0 150.0%*rated current
of motor
0.1 0.0 ×
F1.34
FWD/REV transition
time
0.0 100.0s 0.1s 0.0
F1.35 FWD/REV switch mode
0: over zero freq. switch
1: over start freq. switch
1 0 ×
F1.36
Standby deceleration
time when emergency
brake
0.1 3600.0s 0.1s 1.0