036
4.1 Function Code
F2 Group - Motor Parameters
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
F2.00 Motor type
O: AC asynchronous motor
1: PMSM ( reserved )
Note 1: only closed-loop
vector control is acceptable
by synchronous machine at
present Note 2: this parameter
can not be initialized, please
modify it manually.
1 0 ×
F2.01 Motor's rated power 0.4 999.9KW 0.1KW
Depending
on model
×
F2.02 Motor's rated freq.
0.01Hz ~【F0.15】maximum
freq.
0.01Hz 50.00 ×
F2.03 Motor's rated speed 0 60000RFM 1RFM
Depending
on model
×
F2.04 Motor's rated voltage 0 999V 1V
Depending
on model
×
F2.05 Motor's rated current 0.1 6553.5A 0.1A
Depending
on model
×
F2.06
Stator resistance of
asynchronous motor
0.001 20.000Ω 0.001Ω
Depending
on model
×
F2.07
Rotor resistance of
asynchronous motor
0.001 20.000Ω 0.001Ω
Depending
on model
×
F2.08
Stator and rotor
inductance of
asynchronous motor
0.1 6553.5mH 0.1mH
Depending
on model
×
F2.09
Stator and rotor
mutual inductance af
asynchronous motor
0.1 6553.5mH 0.1mH
Depending
on model
×

Table of Contents