037
4.1 Function Code
F2 Group - Motor Parameters
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
F2.10
No-load current
of asynchronous
motor
0.01 655.35A 0.01A
Depending
on model
×
F2.11-
F2.15
Reserved 0
F2.16 Motor tuning
0: no action
1: static tuning
2: no-load complete tuning
3: on-load complete tuning
1 0 ×
F2.17
pre-excitation time
of asynchronous
motor
0.00 10.00s
0.4 4.0KW 0.05s
5.5 30KW 0.1s
37 132KW 0.30s
160 630KW 0.50s
note: invalid for VF control
0.01s
Depending
on model
×
F3 Group - Reserved Parameters
F4 Group - Speed Loop, Torque and Flux Control Parameters
F4.00
Speed loop (ASR1)
proportional gain
0.000 6.000 0.001 1.000
F4.01
Speed loop (ASR1)
integral time
0.000 32.000s 0.001s 1.000
F4.02
ASR1 󽗉lter time
constant
0.000 0.100s 0.001s 0.000
F4.03
Switch low point
freq.
0.00Hz ~【F4.07】 0.01Hz 5.00