4.1 Function Code
F7 Group - Digital Input and Output Parameters
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
F7.04
Input X5 function
(when F8.21 is
non-zero, default
as function
NO.62)
32: reserved
33: PID control input
34: PID control pause
35: start traverse operation
36: pause traverse operation
37: traverse status reset
38: PLC control input
39: PLC pause
40: PLC reset
41: clear the counter to zero
42: input signal to trigger the
counter
43: timing triggering input
44: timing clearing input
45: input external impulse
frequency (only valid for X6)
46: clear the length information
47: input the signal of length
(only valid for X6)
48: switch speed and torque
control
49: prohibit torque control
50 55: reserved
56 57: reserved
58: start/stop
59: running allowed
60: interlock1
61: interlock2
62: interlock3
63: PFC start/stop
64: A frequency switch B and run
65: First group PID switch to second
group PID
66 69: reserved
1 8 ×
F7.05
Input X6
function
(when F8.21 is
non-zero,
default as
function N0,63 )
1 0 ×
F7.06
Input X7 function
high speed
impulse input
1 45 ×