EasyManua.ls Logo

Sako SKI600 - Page 74

Sako SKI600
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
068
4.1 Function Code
FC Group - Advanced Function and Performance Parameters
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
FC.19 AVR function
LED one's place: AVR
function
0: disabled
1: always enabled
2: only disabled when
decelerating
LED ten's place:
overmodulation
0: disabled
1: enabled
LED hundred's place: dead-
time compensation
0: disabled
1: enabled
LED thousand's place:
harmonic components
optimizing
(reserved)
0: disabled
1: enabled
1 1102 ×
FC.20
Oscillation suppressing
initial freq.
0.00 300.00Hz 0.01
Depending
on model
FC.21 Flux braking 0 100 0: disabled 1 0
FC.22
Energy saving control
factor
0 100 0: disabled 1 0
FC.23 MS priority
0: disabled
1: MS prior to F0.07 setting
1 0 ×