Now you are back in Performance Mode, and the Data Control knob has been
assigned to send Bank MSB values.
A MIDI Bank MSB change will be sent out each time the Data Control knob is
turned. (See the section on MIDI Functions for more information.) The LED display
will show the Bank MSB value (between 0 and 127) as you turn the knob.
Data Control
[Assignable]
Panic Key(F#6)
Pressing the Panic key will send out a Reset All Controllers and All Notes
Off MIDI Message on ALL MIDI Channels 1 - 16. This can be especially useful
for clearing stuck notes when controlling external MIDI devices or software
with the piano.
To use the Panic key to send out a Reset All Controllers and All Notes
Off MIDI Message on All MIDI Channels 1 - 16:
Press the [Voice/Function] button to enter Function Mode.
Voice / -
Function
Press the Program Key (F#6).
Cancel
Panic
Data Contr Assign
Bank MSB
Bank LSB
Program
Default
9
8
7
6
5
4
3
2
1
0
Enter
F#6
NOTE
The Piano Reset procedure described at the beginning of the Additional Features
section also sends out a Reset All Controllers and All Notes Off MIDI
Message, but on MIDI Channel 1 only.
To do a Piano Reset, press the Reverb and Voice/Function buttons at the same time.
For a complete list of MIDI commands sent during a Piano Reset, see Appendix.