EB 8091 EN 3-5
Design and principle of operation
3.4 Technical data
The nameplates on the valve and actuator
provide information on the control valve ver-
sion. See the 'Markings on the device' sec-
tion.
More information is available in Data Sheet
uT8091.
Compliance
The Type3510 Valve bears both the CE and
EAC marks of conformity.
Temperature range
Depending on the version, the control valve
is designed for a temperature range from
–10 to +220°C. The use of an insulating
section or bellows seal can extend the tem-
perature range down to –196 and up to
+450°C (higher temperatures on request)
depending on the properties of the materials
used.
Leakage class
Depending on the version, the following
leakage class according to IEC60534 ap-
plies:
− Leakage class IV with metal seal
− Leakage class V for high-performance
metal seal
Noise emissions
SAMSON is unable to make general state-
ments about noise emissions. The noise emis-
sions depend on the valve version, plant fa-
cilities and process medium.
Note