Troubleshooting
Samsung Electronics 4-94
4-5-35 Outdoor Temperature Sensor Error
(Operation) ×(Reservation) (Blast) ×(Filter) ×(Defrost)
t0VUEPPSUFNQFSBUVSFTFOTPS01&/4)035JTGBVMUZ
t3FGFSUPUIFJOTQFDUJPONFUIPECFMPX
Indoor Unit Display
Judgment Method
Special Cause
Outdoor Unit Display
1. Inspection Method
Did the outside temperature sensor
connector break away from the PCB?
Did the resistance value
significantly stray from the following
temperature table?
After separating the indoor temperature sensor
connector from the PCB, measure the resistance
value between the terminals.
Restart operation after changing the PCB,
Restart operation after connecting
the connector to the PCB.
Change this since it is the fault of the
indoor temperature sensor itself.
Yes
No
No
Yes
Temperature (°C)
70
60
50
40
30
20
10
0
-10
Resistance (KΩ)
2.2
3.0
4.2
5.8
8.3
12.1
18.0
27.3
43.0
Resistance value measure part