EasyManua.ls Logo

Samsung CLX-8540ND - Page 197

Samsung CLX-8540ND
403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Service Manual
4-35
Samsung Electronics
Code
NVM Description
(GUI)
Default
Max
/ Min
Function Description
107-000 Transfer1 High
Voltage(THV) Yellow
65 100/50 * T1 Transfer current (Y,M,C,Bk-Pod) PWM Duty
* This is the high voltage to transfer the toner image on OPC to
the ITB.
* When perfoming the CTD or ACR, it is the same for tranfering
the compensating patch on ITB.
* Current(T1) = 0.1736 * PWM - 3.1603
* This value is the only initial setting of default PWM Duty for the
first transfer.
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically.
107-010 Transfer1 High
Voltage(THV) Magenta
65 100/50
107-020 Transfer1 High
Voltage(THV) Cyan
65 100/50
107-030 Transfer1 High
Voltage(THV) Black (THV
Bias Control)
65 100/50
107-040 Transfer1 High
Voltage(THV) Low
Yellow
53 100/50 * T1 Protection current (Y,M,C,Bk-Pod) PWM Duty
* This is the high voltage to ensure the output stability of HVPS for
no-image area on OPC.
* Current(T1) = 0.1736 * PWM - 3.1603
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically. It never
change.
107-050 Transfer1 High
Voltage(THV) Low
Magenta
53 100/50
107-060 Transfer1 High
Voltage(THV) Low Cyan
53 100/50
107-070 Transfer1 High
Voltage(THV) Low Black
53 100/50
107-080 Transfer2 High
Voltage(THV2)
140 160/65 * T2 transfer current (Simplex printing side) PWM Duty
* This is the high voltage to transfer the toner image on ITB to the
paper for second transfer.
* This is the second transfer high voltage for simplex printing side
that doesn't pass the fuser.
* Current(T2) = 0.2654 x PWM - 9.0191
* The value set on EDC manually is not applied to the real printing.
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically.
107-090 Transfer2 High
Voltage(THV2) Duplex
80 160/65 * T2 transfer current (Duplex printing side) PWM Duty
* This is the high voltage to transfer the toner image on ITB to the
paper for second transfer.
* This is the second transfer high voltage for duplex printing side
that pass the fuser.
* Current(T2) = 0.2654 x PWM - 9.0191
107-100 PreTransfer1 Duty 74 100/50 * T1 transfer system Load recognition current PWM Duty
* This is the high voltage to recognize the total impedance of T1
transfer system that pass the T1 roller rubber, ITB, OPC.
* Current(T1) = 0.1736 * PWM - 3.1603
* The value set on EDC manually is not applied to the real printing.
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically.

Table of Contents