Troubleshooting
Service Manual
4-36
Samsung Electronics
Code
NVM Description
(GUI)
Default
Max
/ Min
Function Description
107-110 PreTransfer2 Duty 105 160/65 * T2 transfer system Load recognition current PWM Duty
This is the high voltage to recognize the total impedance of T2
transfer system that pass the T2 roller rubber, ITB, OPC
* Current(T2) = 0.2654 x PWM - 9.0191
* The value set on EDC manually is not applied to the real printing.
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically.
107-120 Saw Plate Duty (Detack
Bias Control)
90 110/1 * Eraser high voltage PWM Duty of the rear paper
* After second transfer, this high voltage erases the static
electricity from the rear paper.
* (Saw eraser Bias) = -8.4237 x (PWM) + 315.3
* The value set on EDC manually is not applied to the real printing.
* At real printing, the value is applied by the Look-Up Table
considering the environment and life automatically.
109-050 60 gms Temperature
offset
7 14/0 * Fusing temperature variableness of Thin type paper
* Default temperature : 170℃
* Range of variableness : 177 ~ 163℃ (170℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 170℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 170℃
109-060 90 gms Temperature
offset
7 14/0 * Fusing temperature variableness of Plain type paper
* Default temperature : 175℃
* Range of variableness : 182 ~ 168℃ (175℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 175℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 175℃
109-070 Bond Temperature offset 7 14/0 * Fusing temperature variableness of Bond type paper
* Default temperature : 150℃
* Range of variableness : 157 ~ 143℃ (150℃ +/- 7℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 150℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 150℃
109-080 Transparency
Temperature offset
7 12/2 * Fusing temperature variableness of Transparency type paper
* Default temperature : 150 ℃
* Range of variableness : 155 ~ 145℃ (150℃ +/- 5℃)
* In case, the value is more than 7 :
The fuser temperature increases (input value-7)℃ than 150℃
* In case, the value is less than 7 :
The fuser temperature decreases (7-input value)℃ than 150℃