Code
NVM Description
(GUI)
Default
Max
/ Min
Function Description
112-140 Manual Color Regi
X-offset Cyan
100 200/0 * Primary scanning direction offset compared with Black for Cyan.
(Unit : dot )
* In case, the value is more than 100 :
Primary scanning direction of cyan moves to left than black.
* In case, the value is less than 100 :
Primary scanning direction of cyan moves to right than black.
112-150 Manual Color Regi
X-offset Black
100 100/100 * Black is a standard. So you can't change the value.
112-160 Manual Color Regi
Y-offset Yellow
100 200/0 * Secondary scanning direction offset compared with Black for
Yellow. (Unit : dot)
* Secondary scanning direction : Horizontal direction for paper
transfer
* In case, the value is more than 100 :
Secondary scanning direction of yellow moves to bottom than
black.
* In case, the value is less than 100 :
Secondary scanning direction of yellow moves to top than black.