Code
NVM Description
(GUI)
Default
Max
/ Min
Function Description
112-170 Manual Color Regi
Y-offset Magenta
100 200/0 * Secondary scanning direction offset compared with Black for
Magenta. (Unit : dot)
* In case, the value is more than 100 :
Secondary scanning direction of magenta moves to bottom than
black.
* In case, the value is less than 100 :
Secondary scanning direction of magenta moves to top than
black.
112-180 Manual Color Regi
Y-offset Cyan
100 200/0 * Secondary scanning direction offset compared with Black for
Cyan. (Unit : dot)
* In case, the value is more than 100 :
Secondary scanning direction of cyan moves to bottom than black.
* In case, the value is less than 100 :
Secondary scanning direction of cyan moves to top than black.
112-190 Manual Color Regi
Y-offset Black
100 100/100 * Black is a standard. So you can't change the value.