Code
NVM Description
(GUI)
Default
Max
/ Min
Function Description
112-200 Manual Color Regi Width
Yellow
100 200/0 * This vaule adjusts the primary scanning direction width of Yellow
color. It adjusts the left side based on the right of portrait (paper
direction).
* In case, the value is more than 100 :
Primary scanning direction width of yellow increases.
* In case, the value is less than 100 :
Primary scanning direction width of yellow decreases.
112-210 Manual Color Regi Width
Magenta
100 200/0 * This vaule adjusts the primary scanning direction width of
Magenta color. It adjusts the right side based on the left of
portrait (paper direction).
* In case, the value is more than 100 :
Primary scanning direction width of magenta increases.
* In case, the value is less than 100 :
Primary scanning direction width of magenta decreases.