112-220 Manual Color Regi Width
Cyan
100 200/0 * This vaule adjusts the primary scanning direction width of Cyan
color. It adjusts the left side based on the right of portrait (paper
direction).
* In case, the value is more than 100 :
Primary scanning direction width of cyan increases.
* In case, the value is less than 100 :
Primary scanning direction width of cyan decreases.
112-230 Manual Color Regi Width
Black
100 200/0 * This vaule adjusts the primary scanning direction width of Black
color. It adjusts the right side based on the left of portrait (paper
direction).
* In case, the value is more than 100 :
Primary scanning direction width of black increases.
* In case, the value is less than 100 :
Primary scanning direction width of black decreases.
05-100 DADF Top Edge Erase 2 4/0 * This value sets the Top Skip at DADF Copy.
* This value 1 means 1mm skip.
* In case, the value is more than 2 :
Top Skip at DADF copy increases.
* In case, the value is less than 2 :
Top Skip at DADF copy decreases.