4-99
Troubleshooting
● Code : 03-011 ● Error message : Motor does not operate: #03-011. Please turn off then on.
● Symptom : The motor to engage/ disengage the 2
nd
transfer roller does not operate.
● Possible Cause:
1. Harness is defective, Connector is not connected properly.
2. T2 DC Motor is defective.
3. Engine Board is defective.
● Troubleshooting method :
2. Check the following.
-. If the connection is no problem, enter the EDC mode and execute the T2 DC Motor test.
If the Motor is not operate, remove the main drive unit.
'T2&BLDC ITB‘
(CN16, 15pin)
Main Drive Unit
1
2
Main Drive unit
1. Check the following.
-. Check if the Engine Board Harness is defective.
-. Check if the harness is connected to the ‘T2&BLDC ITB’ Connector on Engine Board properly.
To be continued on next page…