EasyManua.ls Logo

Santec TSL-550 - 7-4-1. Command set 1 (Complies with IEEE-488.2)

Default Icon
130 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tunable Semiconductor Laser TSL- 550
7-23
4. TSL-550 Specic command overview
An overview of the specic commands available in Command set 1 is shown in
the following table.
TSL-550 Specic Command List (Command set 1 Group)
Command Description Page
:SPECial:REBoot Resets the device.
7-26
:SYSTem:ERRor? Reads out the error issued. 7-
26
:SYSTem:VERSion? Reads out the version of the rmware. 7-
26
:SYSTem:COMMunicate:GPIB:ADDRess Sets the GPIB address. 7-
26
:SYSTem:COMMunicate:GPIB:ADDRess? Reads out the GPIB address. 7-
26
:SYSTem:COMMunicate:GPIB:DELimiter
Sets the command delimiter for GPIB
communication.
7-
27
:SYSTem:COMMunicate:GPIB:DELimiter?
Reads out the command delimiter for GPIB
communication.
7-
27
:SYSTem:COMMunicate:SERial:SPEed Sets the speed of serial communication. 7-
27
:SYSTem:COMMunicate:SERial:SPEed? Reads out the speed of serial communication. 7-
28
:SYSTem:
COMMunicate:SERial:DELimiter
Sets the command delimiter for serial
communication.
7-2
8
:SYSTem:COMMunicate:SERial:DELimiter?
Reads out the command delimiter for serial
communication
7-2
8
:SYSTem:Lock? Check for Interlock and system lock (option) 7-29
:TRIGger:INPut:EXTernal
Sets Enable/Disable of the external trigger
signal input.
7-29
:TRIGger:INPut:EXTernal?
Reads out the setting of the external trigger
signal input.
7-29
:TRIGger:INPut:STANdby
Puts the device in trigger signal input standby
mode.
7-29
:TRIGger:INPut:STANdby?
Reads out the trigger signal input standby
mode.
7-30
:TRIGger:OUTPut Sets the timing of the trigger signal output. 7-30
:TRIGger:OUTPut?
Reads out the timing setting of the trigger
signal output.
7-30
:TRIGger:OUTPut:STEP[:WIDTh] Sets the interval of the trigger signal output. 7-30
:TRIGger:OUTPut:STEP[:WIDTh]?
Reads out the interval of the trigger signal
output.
7-31
[:SOURce]:COHCtrl Turns ON/OFF the coherence control. 7-31
[:SOURce]:COHCtrl? Reads out the state of the coherence control. 7-31
[:SOURce]:POWer:STATe Sets ON/OFF the LD. 7-31
[:SOURce]:POWer:STATe? Reads out the ON/OFF status of the LD. 7-32
[:SOURce]:POWer:ATTenuation Sets the attenuator value. 7-32
[:SOURce]:POWer:ATTenuation? Reads out the attenuator value. 7-32
[:SOURce]:POWer:ATTenuation:AUTo Switches to Auto/Manual for the power control. 7-32
[:SOURce]:POWer:ATTenuation:AUTo? Reads out the setting of the power control. 7-33

Table of Contents