SCC1000C Crawler Crane — Maintenance Manual
4.3.3 Relling the Coolant
Procedures for relling coolant:
1. Open the radiator cap slowly to release the
system pressure after the engine cool down.
2. Visually check whether the coolant level is above
the inspection hole on the expansion tank. If not,
rell the coolant.
3. Replenish coolant level in the tank through the
inlet port of the expansion tank. If the radiator
and the expansion tank are full of coolant, start
the engine to run at idle speed for approx. 5
minutes. Then the coolant level will decrease.
4. Shut off the engine and remove the key. Refill
the coolant to the level of the inspection hole of
the expansion tank.
5. Replace the radiator cap.
Coolant Filling Port
-- Only open the cap of the engine’s
cooling system after the engine’s
cooled down, otherwise, the system
will be subject to pressure and could
cause an accident�
-- While lling the cooling system, make
sure not to form an air pocket� The
absorption of air in the system will
lead to engine damage�
4�3�2 Checking the Coolant
Visually inspect whether the coolant level reaches
the height of the inspection hole, and rell coolant
if not.
Water cooler
Engine
Intercooler
Water level
detect port
Coolant
lling port
T103 7009