Section 1 Maintenance
SCC1000C Crawler Crane — Maintenance Manual
4�4�2 Checking the Filter Element
It is recommended to have the spare lter elements
on hand for standby. While cleaning other parts,
these spare parts can be used.
Regularly maintain the air lter.
1. Remove the lter core,
2. Visually check whether there is any appearance of
damage,
3. Gently wipe,
4. Wipe inside the casing of the lter as shown in
the picture,
5. When there is no damage, reinstall it, otherwise
replace it.
CAUTION
-- Wear protective gloves and clothing
while using compressed air to clean the
filter element� The air pressure should
not exceed maximum 5 bars (72�57psi)�
-- Do not clean the lter element by patting
or tapping�
-- Do not use damaged lter element.
Checking Procedures