-50-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
22 Measured Blue - Luma 0 - 32767 405/184/323/347
30 Measured Cyan - X 0 - 1000 0/0/0/0
31 Measured Cyan - Y 0 - 1000 0/0/0/0
32 Measured Cyan - Luma 0 - 32767 0/0/0/0
40 Measured Magenta - X 0 - 1000 0/0/0/0
41 Measured Magenta - Y 0 - 1000 0/0/0/0
42 Measured Magenta - Luma 0 - 32767 0/0/0/0
50 Measured Yellow - X 0 - 1000 0/0/0/0
51 Measured Yellow - Y 0 - 1000 0/0/0/0
52 Measured Yellow - Luma 0 - 32767 0/0/0/0
60 Measured Half White - X 0 - 1000 310/315/0/0
61 Measured Half White - Y 0 - 1000 335/336/0/0
62 Measured Half White - Luma 0 - 32767 3953/2948/0/0
70 Measured Full White - X 0 - 1000 315/320/307/307
71 Measured Full White - Y 0 - 1000 343/350/336/340
72 Measured Full White - Luma 0 - 32767 11860/7462/10160/11420
100 Measured Data Update Execute the update when the value is set to 10. 0 - 10 -
160 VIDI
0 Brightness (Wheel)-Dynamic Brightness Wheel (Brightness) 0 - 10 4
1 Brightness (Wheel)-Not Dynamic Brightness Wheel (Color) 0 - 10 2
2 Color (Wheel)-Dynamic Brightness Wheel (Brightness) 0 - 10 5
3 Color (Wheel)-Not Dynamic Brightness Wheel (Color) 0 - 10 3
161 Lamp Sync
0 Brightness (Wheel)-x2 Mode 0 - 65535 1130
1 Brightness (Wheel)-x3 Mode 0 - 65535 900
2 Color (Wheel)-x2 Mode 0 - 65535 429
3 Color (Wheel)-x3 Mode 0 - 65535 352
200 Option
0 Logo Display Prohibition 0:Menu 1:Forced 0 - 1 0
1 RS232C Baud rate 0: 19200bps 1: 9600bps 0 - 1 0
4 CABLE SW Long Cable 0: Disable 1: Enable 0 - 1 0
5 PW Debug Command Enable
0: Disable (Serial Command Enable)
1: Enable (PW Debug Mode)
0 - 1 0
6 Device Refresh Disable 0: Enable 1: Disable 0 - 1 0
11 HDCP EDID Data Setting 0: DVI EDID Data, 1: HDCP EDID Data 0 - 1 1
15 Lens Shift Centering Setting * Reset Centering position when the value is set to 10. 0 - 10 0
21 Lamp Warning Time (NORMAL) 1-16 4
22 Lamp Warning Time (ECO) 1-16 6
23 Lamp Warning Time (HIGH) 1-16 4
24 Projector Time REset Times 0 - 255 0
50 Lamp Replacement Display 1:On 0:Off 0 - 1 1
51 Filter Warning Display 1:On 0:Off 0 - 1 1
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Executed Times Read only 0 - 255 0
55 Motor Stop Motor Operation 0: Enable 1: Disable 0 - 1 0
56 Menu Position (X) X Offset 0 - 1024 0
57 Menu Position (Y) Y Offset 0 - 1024 0
58 Lamp Go Out Lamp goes out 0 - 1 0
59 LENS LOCK Warning Display 0: Enable 1: Disable 0 - 1 0
62 Color Wheel Warning 0: Enable 1: Disable 0 - 1 0
65 Peltier PWM Enable Peltier Drive PWM 0: Auto, 1: Manual, 2: Disable 0 - 2 0
66 Peltier PWM High Term 0 - 600 600
67 Peltier PWM Low Term 0 - 600 600
70 ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
71 ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
72 Component/RGB Auto Switch 0: Disable 1: Enable 0 - 1 1
80 Destination Language Set at Shipping 0:English 1:Japanese 0 - 1 0
100 Disable Auto Picture Control 0 : Normal operation 1 : Auto Picture Control Off 0-1 Initial: 1 Shipping 0
140 Offset Add Setting Status 0: Not use Offset Add, 1: Use Offset Add (Read only) - 0
141 Offset Add Setting Change Change the Offset Add Setting when the value is set to 10. 0 - 10 0
142 Offset Value Offset Add Value at Shutdwon Temp(Read only) - 0
143 Offset Add Execute Times (Read only) 0 - 255 0
144 Offset Add Cancel Times (Read only) 0 - 255 0
201 Option (Signal)
0 FrameLock Option Frame Lock Setting 1: Normal(PC) 0: OFF 0 - 1 1