Electrical Adjustment
Grp / No. Item Function Range Initial Note
1 Dither Enable 0: Disable 1: Enable 0 - 1 1
2 VSBEG 0 - 15 2
3 Field Sense Invert Enable 0: Disable 1: Enable 0 - 1 0
204 Simulation mode
0 PW392C Enable 0: Off, 1: On 0 - 1 0
1 PW610 Enable 0: Off, 1: On 0 - 1 0
205 Spread Spectrum
0 Enable 0 - 1 1
1 Spread Rate 0 - 300 100
2 Spread Frequency 0 - 500 150
210 Lamp Control
0 Dimmer SW 0:Auto 1:Manual 0 - 1 0
1 Manual Control
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
0 - 15 0
2 DIMMER_CTRL_LEVEL1 Y Level1 Data for Dimmer 0 - 255 7
3 DIMMER_CTRL_LEVEL2 Y Level2 Data for Dimmer 0 - 255 14
4 DIMMER_CTRL_LEVEL3 Y Level3 Data for Dimmer 0 - 255 21
5 DIMMER_CTRL_LEVEL4 Y Level4 Data for Dimmer 0 - 255 28
6 DIMMER_CTRL_LEVEL5 Y Level5 Data for Dimmer 0 - 255 35
7 DIMMER_CTRL_LEVEL6 Y Level6 Data for Dimmer 0 - 255 42
8 DIMMER_CTRL_LEVEL7 Y Level7 Data for Dimmer 0 - 255 49
9 DIMMER_CTRL_LEVEL8 Y Level8 Data for Dimmer 0 - 255 56
10 DIMMER_CTRL_LEVEL9 Y Level9 Data for Dimmer 0 - 255 63
11 DIMMER_CTRL_LEVEL10 Y Level10 Data for Dimmer 0 - 255 70
12 DIMMER_CTRL_LEVEL11 Y Level11 Data for Dimmer 0 - 255 77
13 DIMMER_CTRL_LEVEL12 Y Level12 Data for Dimmer 0 - 255 84
14 DIMMER_CTRL_LEVEL13 Y Level13 Data for Dimmer 0 - 255 91
15 DIMMER_CTRL_LEVEL14 Y Level14 Data for Dimmer 0 - 255 98
16 DIMMER_CTRL_LEVEL15 Y Level15 Data for Dimmer 0 - 255 105
17 DIMMER_AVERAGE_POINT Y Average Point 1 - 16 4
18 DIMMER_AVERAGE_DATA Y Average Data (Read only) - -
19 DIMMER_LEVEL_AUTO Current Y Level (Read only) - -
20 DIMMER_LEVEL_NORMAL Dim Level at Normal 0 - 15 15
21 DIMMER_LEVEL_ECO Dim Level at Eco 0 - 15 0
23 VOLTAGE_LEVEL Lamp Voltage (Read only) - -
24 DIMMER_LEVEL_HIGH Dim Level at High 0 - 15 15
220 Projector Error Log
0 Warning_Log_1 Latest Error log 0 - 32767 0
: : : : :
49 Warning_Log_50 50th Error log 0 - 32767 0
50 Warning_Log Reset Log is cleared when the value is set to 10. 0 ~ 10 0
235 Shutter
0 PRE_MOTION Shutter Warm - up Operation (0: Yes, 1: No) 0 - 1 Initial: 1 / Shipping: 0
1 CMP_TRM Chattering Detecting Term 0 - 32767 7000
2 OUT_DLY_TRM Output Term 0 - 32767 15000
3 CMP_CHK_CNT Count of Information Sync 0 - 15 5
4 OPEN_DLY Open Output Delay 0 - 63 30
5 CLOSE_DLY Close Output Delay 0 - 63 30
6 Position Check Time Position Check Time 1 - 255 20
7 Stop Mode
Shutter Operation in Stop Mode
0:Free, 1:Brake
0 - 1 1
8 Enable Close Cmd
Shutter Close Command
0:Disable, 1:Enable
0 - 1 1
10 Sutter Management Upper Time 180 - 999 480
236 Lamp Mode Switch
0 2 Lamp Mode 0 - 99 0
1 Lamp1 Mode 0 - 99 0
2 Lamp2 Mode 0 - 99 0
240 Flow Calibration
0 Flow Calibration Exe *
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1 0