Electrical Adjustment
Grp / No. Item Function Range Initial Note
1 Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
- 255
2 Clog Check Enable Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable) 0 - 1 Initial: 0 / Shipping: 1
4 Time Limit Auto Scroll Enable Auto Scroll 0: Disable, 1: Enable 0 - 1 1
5 Clog Auto Cooling Enable Auto Cooling at Clog 0: Disable, 1: Enable 0 - 1 1
6 Scroll Fail Auto Cooling Enable Auto Cooling at Scroll Error 0: Disable, 1: Eanble 0 - 1 1
7 Time Force Scroll Enable Forced Scroll at Filter Time 0: Disable, 1: Enable 0 - 1 0
241 Flow Ideal Data (Value will be set after calibration)
0 Flow Ideal Data 1 Flow Sensor Theory Value No.1 Corresponding to Fan Volt No.1 0 - 1023 365
1 Flow Ideal Data 2 Flow Sensor Theory Value No.2 Corresponding to Fan Volt No.2 0 - 1023 480
2 Flow Ideal Data 3 Flow Sensor Theory Value No.3 Corresponding to Fan Volt No.3 0 - 1023 529
3 Flow Ideal Data 4 Flow Sensor Theory Value No.4 Corresponding to Fan Volt No.4 0 - 1023 573
4 Flow Ideal Data 5 Flow Sensor Theory Value No.5 Corresponding to Fan Volt No.5 0 - 1023 609
5 Flow Ideal Data 6 Flow Sensor Theory Value No.6 Corresponding to Fan Volt No.6 0 - 1023 1023
6 Flow Ideal Data 7 Flow Sensor Theory Value No.7 Corresponding to Fan Volt No.7 0 - 1023 1023
7 Flow Ideal Data 8 Flow Sensor Theory Value No.8 Corresponding to Fan Volt No.8 0 - 1023 1023
242 Flow Calib. Fan Volt (Not Memorized)
0 Flow Calib Fan Volt 1 Flow Sensor Calibration Fan Volt No.1 [V x10] 0 - 255 65
1 Flow Calib Fan Volt 2 Flow Sensor Calibration Fan Volt No.2 [V x10] 0 - 255 95
2 Flow Calib Fan Volt 3 Flow Sensor Calibration Fan Volt No.3 [V x10] 0 - 255 110
3 Flow Calib Fan Volt 4 Flow Sensor Calibration Fan Volt No.4 [V x10] 0 - 255 125
4 Flow Calib Fan Volt 5 Flow Sensor Calibration Fan Volt No.5 [V x10] 0 - 255 138
5 Flow Calib Fan Volt 6 Flow Sensor Calibration Fan Volt No.6 [V x10] 0 - 255 255
6 Flow Calib Fan Volt 7 Flow Sensor Calibration Fan Volt No.7 [V x10] 0 - 255 255
7 Flow Calib Fan Volt 8 Flow Sensor Calibration Fan Volt No.8 [V x10] 0 - 255 255
243 Flow Calib Effective Difference (Not Memorized)
0 Flow Calib Effective Diff 1 Flow Sensor Calibration Range Diff No.1 [ADC] 0 - 1023 250
1 Flow Calib Effective Diff 2 Flow Sensor Calibration Range Diff No.2 [ADC] 0 - 1023 250
2 Flow Calib Effective Diff 3 Flow Sensor Calibration Range Diff No.3 [ADC] 0 - 1023 250
3 Flow Calib Effective Diff 4 Flow Sensor Calibration Range Diff No.4 [ADC] 0 - 1023 250
4 Flow Calib Effective Diff 5 Flow Sensor Calibration Range Diff No.5 [ADC] 0 - 1023 250
5 Flow Calib Effective Diff 6 Flow Sensor Calibration Range Diff No.6 [ADC] 0 - 1023 1023
6 Flow Calib Effective Diff 7 Flow Sensor Calibration Range Diff No.7 [ADC] 0 - 1023 1023
7 Flow Calib Effective Diff 8 Flow Sensor Calibration Range Diff No.8 [ADC] 0 - 1023 1023
244 Flow Clog Threshold (Not Memorized )
0 Flow Clog Threshold 1 Flow Sensor Clogged Threshold No.1[ADC] 0 - 1023 48
1 Flow Clog Threshold 2 Flow Sensor Clogged Threshold No.2[ADC] 0 - 1023 56
2 Flow Clog Threshold 3 Flow Sensor Clogged Threshold No.3[ADC] 0 - 1023 70
3 Flow Clog Threshold 4 Flow Sensor Clogged Threshold No.4[ADC] 0 - 1023 65
4 Flow Clog Threshold 5 Flow Sensor Clogged Threshold No.5[ADC] 0 - 1023 62
5 Flow Clog Threshold 6 Flow Sensor Clogged Threshold No.6[ADC] 0 - 1023 1023
6 Flow Clog Threshold 7 Flow Sensor Clogged Threshold No.7[ADC] 0 - 1023 1023
7 Flow Clog Threshold 8 Flow Sensor Clogged Threshold No.8[ADC] 0 - 1023 1023
245 Filter Roll
0 Take Up Bend Remove Filter Flexure Starts when the Value is set to 1. 0 - 1 0
1 Take Up Times Remaining Times of Filter Scroll (Read only) - -
2 Take Up Time Reset
Filter Scroll Times Reset
Resets Remaining Scroll Times when the Value is set to 10.
0 - 10 0
3 Scroll Counter Reset Time Scroll Counter Reset Times (Read only) 0 - 255 -
4 Scroll Information Cartridge No 0 - 2 0
246 Flow Clog Monitor (Read only)
0 Real Flow Data Real Flow Data [ADC] (Read only) 0 - 1023 -
1 Ideal Flow Data Theory Flow Data (Read only) 0 - 1023 -
2 Flow Difference Data Flow Difference Data [ADC] (Read only) -1023 - 1023 -
3 Clog Detect Flow Difference Data Difference Data to judge the Filter Clogged [ADC] (Read only) 0 - 1023 -
4 Warn Detect Flow Difference Data
Difference Data to judge the Filter Clogged Warning [ADC] (Read
only)
0 - 1023 -
5 Press Add Data Add Data by Air Pressure (Read only) 0 - 1023 -
6 Filter Scroll Timer Timer for Filter Scroll [hour] (Read only) 0 - 32767 -