-54-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
4 Press Sensor Calibration Log
Calibration Log
0: Normal
10: Out of Range Mini
20: Out of Range Max
99: Calibration Not Executed
- 99
250 Fan Voltage Adjustment *
0 Fan A Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0-255 65
1 Fan A Max Adjust (DAC) 0-255 220
2 Fan B/C Min Adjust (DAC) 0-255 55
3 Fan B/C Max Adjust (DAC) 0-255 215
4 Fan D/E Min Adjust (DAC) 0-255 85
5 Fan D/E Max Adjust (DAC) 0-255 220
6 Fan F/G Min Adjust (DAC) 0-255 95
7 Fan F/G Max Adjust (DAC) 0-255 220
8 Fan H Min Adjust (DAC) 0-255 65
9 Fan H Max Adjust (DAC) 0-255 220
252 Fan Option
1 Safety Switch Safety Application use 0-8 0
2 Fan Manual Switch Fan Manual SW (0: Auto 1: Manual) 0-1 0
3 Fan A Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0-255 100
4 Fan B/C Manual Voltage 0-255 100
5 Fan D/E Manual Voltage 0-255 100
6 Fan F/G Manual Voltage 0-255 100
7 Fan H Manual Voltage 0-255 100
10 Angle Data A Angle Data A (Read only) - -
11 Angle Data B Angle Data B (Read only) - -
12 Press Data Press Data (Read only) - -
L1
L3
L4
L5
L6
L7
L8
112.5°
247.5°
67.5°
292.5°
22.5°
157.5°
202.5°337.5°
L2
Definition of Slant
L1 337.5° ~ 22.5°
L2 22.5° ~ 67.5°
L3 67.5° ~ 112.5°
L4 112.5° ~ 157.5°
L5 157.5° ~ 202.5°
L6 202.5° ~ 247.5°
L7 247.5° ~ 292.5°
L8 292.5° ~ 337.5°
253 Fan Temp Error Setting (Memorized) L1 L2 L3 L4 L5 L6 L7 L8
5 Temp A Warning (Normal) Temp A (Room) to judge the Temp Error at Normal 30-100 45 45 45 45 45 45 45 45
6 Temp B Warning (Normal) Temp B (Optical) to judge the Temp Error at Normal 30-100 75 75 75 75 75 75 75 75
7 Temp C Warning (Normal) Temp C (DMD) to judge the Temp Error at Normal 30-100 70 70 70 70 70 70 70 70
8 Temp B-A Warning (Normal) Temp B - A (Filter Clogged) to judge the Temp Error at Normal 0-100 45 45 45 45 45 45 45 45
9 Temp C-A Warning (Normal) Temp C - A (Filter Clogged) to judge the Temp Error at Normal 0-100 40 40 40 40 40 40 40 40
10 Temp A Warning (Eco) Temp A (Room) to judge the Temp Error at Eco 30-100 45 45 45 45 45 45 45 45
11 Temp B Warning (Eco) Temp B (Optical) to judge the Temp Error at Eco 30-100 75 75 75 75 75 75 75 75
12 Temp C Warning (Eco) Temp C (DMD) to judge the Temp Error at Eco 30-100 70 70 70 70 70 70 70 70
13 Temp B-A Warning (Eco) Temp B - A (Filter Clogged) to judge the Temp Error at Eco 0-100 45 45 45 45 45 45 45 45
14 Temp C-A Warning (Eco) Temp C - A (Filter Clogged) to judge the Temp Error at Eco 0-100 40 40 40 40 40 40 40 40
15 Temp A Warning Offset (Temp)
Temp Warning Offset (Temp)
0-100 13
16 Temp B Warning Offset (Temp) 0-100 13
17 Temp C Warning Offset (Temp) 0-100 13
18 Temp B-A Warning Offset (Temp) 0-100 13
19 Temp C-A Warning Offset (Temp) 0-100 13
20 Temp A Warning Offset (Time)
Time Warning Offset (Time)
0-40 3
21 Temp B Warning Offset (Time) 0-40 3
22 Temp C Warning Offset (Time) 0-40 3
23 Temp B-A Warning Offset (Time) 0-40 3
24 Temp C-A Warning Offset (Time) 0-40 3
L1
L3
L4
L5
L6
L7
L8
112.5°
247.5°
67.5°
292.5°
22.5°
157.5°
202.5°337.5°
L2
Definition of Slant
L1 337.5° ~ 22.5°
L2 22.5° ~ 67.5°
L3 67.5° ~ 112.5°
L4 112.5° ~ 157.5°
L5 157.5° ~ 202.5°
L6 202.5° ~ 247.5°
L7 247.5° ~ 292.5°
L8 292.5° ~ 337.5°
254 Fan Control Range Setting (Temp/Spinning) L1 L2 L3 L4 L5 L6 L7 L8