EasyManua.ls Logo

Sanyo PDG-DHT8000L - Page 55

Sanyo PDG-DHT8000L
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-55-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
16 Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp at Normal
20-100 27 27 27 27 27 27 27 27
17 Normal Fan Control Max Temp 20-100 37 37 37 37 37 37 37 37
18 Normal Fan A Min
Fan Voltage Set at Normal (Min/Max) (V)
0000-9990 63 63 75 75 75 75 75 63
19 Normal Fan A Max 0000-9990 80 80 80 80 80 80 80 80
20 Normal Fan B/C Min 0000-9990 50 70 80 80 80 80 80 70
21 Normal Fan B/C Max 0000-9990 50 70 80 80 80 80 80 70
22 Normal Fan D/E Min 0000-9990 72 72 72 72 72 72 72 72
23 Normal Fan D/E Max 0000-9990 138 138 138 138 138 138 138 138
24 Normal Fan F/G Min 0000-9990 88 88 88 103 103 103 88 88
25 Normal FanF/G Max 0000-9990 138 138 138 138 138 138 138 138
26 Normal Fan H Min 0000-9990 75 75 75 75 75 75 75 75
27 Normal FanH Max 0000-9990 138 138 138 138 138 138 138 138
32 Eco1 Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco1
20-100 27 27 27 27 27 27 27 27
33 Eco1 Fan Control Max Temp 20-100 37 37 37 37 37 37 37 37
34 Eco1 Fan A Min
Fan Voltage Set at Eco1 (Min/Max) (V)
0000-9990 50 50 59 59 59 59 59 50
35 Eco1 Fan A Max 0000-9990 55 55 59 59 59 59 59 55
36 Eco1 Fan B/C Min 0000-9990 40 60 70 70 70 70 70 60
37 Eco1 Fan B/C Max 0000-9990 40 60 70 70 70 70 70 60
38 Eco1 Fan D/E Min 0000-9990 58 58 58 58 58 58 58 58
39 Eco1 Fan D/E Max 0000-9990 125 125 125 125 125 125 125 125
40 Eco1 Fan F/G Min 0000-9990 78 78 78 78 78 78 78 78
41 Eco1 Fan F/G Max 0000-9990 125 125 125 125 125 125 125 125
42 Eco1 Fan H Min 0000-9990 65 65 65 65 65 65 65 65
43 Eco1 Fan H Max 0000-9990 120 120 120 120 120 120 120 120
48 Eco2 Fan Control Min Temp
Temp Sensor Control Start/End Temp at Eco2
20-100 27 27 27 27 27 27 27 27
49 Eco2 Fan Control Max Temp 20-100 37 37 37 37 37 37 37 37
50 Eco2 Fan A Min
Fan Voltage Set at Eco2 (Min/Max) (V)
0000-9990 50 50 59 59 59 59 59 50
51 Eco2 Fan A Max 0000-9990 55 55 59 59 59 59 59 55
52 Eco2 Fan B/C Min 0000-9990 40 60 70 70 70 70 70 60
53 Eco2 Fan B/C Max 0000-9990 40 60 70 70 70 70 70 60
54 Eco2 Fan D/E Min 0000-9990 70 70 70 70 70 70 70 70
55 Eco2 Fan D/E Max 0000-9990 130 130 130 130 130 130 130 130
56 Eco2 Fan F/G Min 0000-9990 85 85 85 85 85 85 85 85
57 Eco2 Fan F/G Max 0000-9990 130 130 130 130 130 130 130 130
58 Eco2 Fan H Min 0000-9990 75 75 75 75 75 75 75 75
59 Eco2 Fan H Max 0000-9990 130 130 130 130 130 130 130 130
255 Fan Start/Cooling Setting
0 Fan A Initial Volt
Fan Start Voltage (0.1V)
0-255 70
1 Fan B/C Initial Volt 0-255 70
2 Fan D/E Initial Volt 0-255 70
3 FanF/G Initial Volt 0-255 70
4 FanH Initial Volt 0-255 70
8 Cooling Time Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 50
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
256 Fan Lamp Voltage Lower Setting
0 Lamp Voltage Current Voltage (V) 0 - 255 -
1 Lamp Volt Threshold 30 - 90 30
2 Fan1 Speed Gain 0 - 1500 0
259 Fan Air Pressure Setting
0 Press Source Range Low
Pressure Sensor Control Range Setting (AD)
0-1024 645
1 Press Source Range High 0-1024 325
2 Press Fan Add Range High
Pressure Sensor Fan Control Add. Voltage (x0.1)
0 - 2000 0
3 Press Fan Add Range Low 0 - 2000 65
4 Temp C-A Upward High Fan Voltage Add Upward (Sensor A-D) High 0 - 1000 25
5 Temp C-A Upward Low Fan Voltage Add Upward (Sensor A-D) Low 0 - 1000 23
6 Temp C-A Downward High Fan Voltage Add Downward (Sensor A-D) High 0 - 1000 22
7 Temp C-A Downward Low Fan Voltage Add Downward (Sensor A-D) Low 0 - 1000 21
260 Auto Calibration (Common)
0 Execute Calibration *
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
0 - 1 0
1 Loop Count Max Times of Calibration 1 - 30 8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9 0

Table of Contents