-42-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
33 wCoeMax 1000 0 - 100
Group 230 VBI Slice Level
0 Generic Initial Slice Level 9 0 - 255
1 Generic High Level Threshold 0 0 - 255
2 Generic Low Level Threshold 0 0 - 255
3 Generic Minimum Low Level 0 0 - 255
4 Generic Maximum High Level 255 0 - 255
Group 250 FAN Voltage Adjutment
0 Fan1 Min. Adjust (DAC) 28 0 - 255
1 Fan1 Max. Adjustt(DAC) 205 0 - 255
2 Fan2 Min. Adjust (DAC) 36 0 - 255
3 Fan2 Max. Adjust (DAC) 207 0 - 255
4 Fan3 Min. Adjust (DAC) 30 0 - 255
5 Fan4 Max. Adjust (DAC) 235 0 - 255
6 Not used
7 Not used
Group 252 Fan Option
0 Hi-Land Switch
0: Normal
1: Hi-Land Mode "On1"
2: HiLand Mode "On2"
0 - 2 Read only
1 Safety Switch For Safety Application purpose 0 0,3-6
2 Fan Manual Switch 0: Auto, 1: Manual 0 0 - 3
3 Fan1 Manual Voltage Fan Voltage (x0.1V) 100 0 - 255
4 Fan2 Manual Voltage Fan2 Voltage (x0.1V) 100 0 - 255
5 Fan3 Manual Voltage Fan3 Voltage (x0.1V) 100 0 - 255
6 Not used
Group 253 FAN Error Setting
A B C D E F
A: Normal (OFF) B: Normal/Ceiling (OFF)
C: Hi-Land (ON1) D: Hi-Land/Ceiling(ON1)
E: Hi-Land (ON2) F: Hil-Land/Ceiling(ON2)
5 Temp A Warning (Normal)
Temperature A to judge the Temp. Failure
Outside at Normal
43 43 0 0 40 40 30-100
6 Temp B Warning (Normal)
Temperature B to judge the Temp. Failure
Panel at Normal
52 52 0 0 52 52 30-100
7 Temp C Warning (Normal)
Temperature C to judge the Temp. Failure
Lamp at Normal
60 60 0 0 55 55 30-100
8 Temp B-A Waninig (Normal)
Temperature B-A to judge the Temp. Failure
Filter Cloggled at Normal
100 100 100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temperature C-A to judge the Temp. Failure
Filter Cloggled at Normal
100 100 100 100 100 100 0-100
10 Temp A Warning (Eco)
Temperature A to judge the Temp. Failure
Outside at Eco
42 42 0 0 40 40 30 - 100
11 Temp B Warning (Eco)
Temperature B to judge the Temp. Failure
Panel at Eco
54 54 0 0 50 50 0 - 100
12 Temp C Warning (Eco)
Temperature C to judge the Temp. Failure
Lamp at Eco
60 60 0 0 52 52 0 - 100
13 Temp B-A Waninig (Eco)
Temperature B-A to judge the Temp. Failure
Filter Cloggled at Eco
100 100 100 100 100 100 0 - 100
14 Temp C-A Warning (Eco)
Temperature C-A to judge the Temp. Failure
Filter Cloggled at Eco
100 100 100 100 100 100 0 - 100
15 Temp A Warning Offset (Temp) 5 0 - 100
16 Temp B Warning Offset (Temp) 5 0 - 100
17 Temp B Warning Offset (Temp) 10 0 - 100
18 Temp B-A Warning Offset (Temp) 0 0 - 100
19 Temp C-A Warning Offset (Temp) 0 0 - 100
20 Temp A Warining Offset (Time) 3 0 - 5
21 Temp B Warning Offset (Time) 3 0 - 5
22 Temp B Warning Offset (Time) 3 0 - 5
23 Temp B-A Warning Offset (Time) 3 0 - 5
24 Temp C-A Warning Offset (Time) 3 0 - 5
Group 254 FAN Control Range Setting
A B C D E F
A: Normal (OFF) B: Normal/Ceiling (OFF)
C: Hi-Land (ON1 DIF) D: Hi-Land/Ceiling(ON1 DIF)
E: Hi-Land (ON2) F: Hil-Land/Ceiling(ON2
10 Normal Fan Control Min. Temp Temp Sensor Control Start/End at Normal 35 35 0 0 32 32 20 - 100
11 Normal Fan Control Max. Temp 40 40 0 0 38 38 20 - 100
12 Normal Fan1 Min. Fan Voltage at Normal (x0.1V) 65 65 -10 -10 125 125 0 - 255
13 Normal Fan1 Max. 135 135 0 0 135 135 0 - 255
14 Normal Fan2 Min. 65 65 -10 -10 90 90 0 - 255
15 Normal Fan2 Max. 120 120 0 0 135 135 0 - 255
16 Normal Fan3 Min. 77 77 -5 -5 80 80 0 - 255
17 Normal Fan3 Max. 90 90 -5 -5 100 100 0 - 255
18 Not used 9999 -
19 Not used 9999 -
20 Eco Fan Control Min. Temp Fan Voltage at Eco (x0.1V) 36 36 0 0 32 32 20 - 100