-43-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
21 Eco Fan Control Max. Temp 39 39 0 0 38 38 20 - 100
22 Eco Fan1 Min. 45 45 -10 -10 110 110 0 - 255
23 Eco Fan1 Max. 120 120 0 0 120 120 0 - 255
24 Eco Fan2 Min. 50 50 -10 -10 85 85 0 - 255
25 Eco Fan2 Max. 100 100 0 0 100 100 0 - 255
26 Eco Fan3 Min. 55 55 -5 -5 60 60 0 - 255
27 Eco Fan3 Max. 65 65 -5 -5 80 80 0 - 255
28 Not used 9999
29 Not used 9999
Group 255 FAN Start/Cooling Setting
0 Fan1 Initial Volt Fan Voltage at Startup (x0.1V) 50 0 - 255
1 Fan2 Initial Volt 50 0 - 255
2 Fan3 Initial Volt 50 0 - 255
3 Not used 9999
4 Fan1 Cooling Speed Fan Voltage at Power Off (x0.1V) 45 0 - 255
5 Fan2 Cooling Speed 60 0 - 255
6 Fan3 Cooling Speed 135 0 - 255
7 Not used 9999
8 Cooling Time L1 Cooling Time at L1 (x 30 sec.) 1 1 - 15
9 Cooling Time L2 Cooling Time at L2 (x 30 sec.) 3 1 - 15
10 Temp Error Cooling Time Cooling Time at Temp Error (x 30sec.) 3 1 - 15
11 onStart Cooling Start Threshold Cooling Start Threshold Temp at On Start 38 0 - 100
12 After Shutdown Cooling Cooling On/Off After Shutdown 1 0 - 1
Group 256 FAN Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (x0.1V) -- 0 - 255
1 Lamp Vol Threshold
Thereshold Voltage to judge the Low Lamp
Voltage
0 30 - 90
2 Fan1 Speed Gain Fan Voltage Add Value at Min (x0.1V) 10 0 - 255
3 Fan2 Speed Gain 10 0 - 255
4 Fan3 Speed Gain 10 0 - 255
5 Not used
Group 257 FAN Dimmer Setting
0 Dimmer Avarage Check Period
Avarage Time to Measurement
0: 10 sec, 1:30 sec, 2: 60 sec, 3: 90 sec. ....
1 0 - 10
1 Dimmer Average Average Dimmer
2 Last Voltage Difference Last Voltage Dfference (x0.1V)
3 Voltage Difference Goal Turget Voltage Difference (0.1V)
Group 258 Fan Option for Network Model
0 Standby Cooling Check Cycle Temp A Check Period in Standby 5 -
1 Cooling Threshold Cooling Start Temp at Temp A 40 -
2 Standby Cooling Enable Cooling in Stanby Enable 1 0 - 1
Group 260 Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when changing
the Value to 1 (PC White 100%)
1 Loop Count
Maximum Execution Times (OFFSET-
>GAIN)
10 1 - 30
2 Auto Status Result of Auto-Calibration (Last Memory) 0 0 / 1 / 9 0: OK, 1: Adjusting,2: Error * ReadOnly
3 AutoWait Wait Value for each setting 1 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 2 1 - 255
Group 261 Auto Calibration (RGB)
0 OFFSET AREA H START Black Level Acquiring Area H-Start Position 975 0 - 1000
1 OFFSET AREA V START Black Level Acquiring Area V-Start Position 500 0 - 1000
2 GAIN AREA H START White Level Acquiring Area H-Start Position 25 0 - 1000
3 GAIN AREA V START White Level Acquiring Area V-Start Position 500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT Black/White Level Acquiring Area Height 9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 3 0 - 127
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 127
8 GAIN target Target Value of White Level Adj. 238 0 - 255
9 GAIN torelance Torelance of White Level Adj. 1 1 - 255
Group 262 Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 50 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0 - 1000
6 Image Area H Width Image Level Acquiring Area 8 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 217 0 - 255
11 Gain Tolerance Torelance of Level Adj. 1 0 - 255
12 Delta Gain Deviation Width of Gain Value 9 0 - 255
Group 264 Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START Y - Offset Acquiring Area H-Start Position 925 0 - 1000
1 Y-OFFSET AREA V START Y - Offset Acquiring Area V-Start Position 500 0 - 1000
2 CB - OFFSET AREA H START CB - Offset Acquiring Area H-Start Position 925 0 - 1000 If not used: use Y's value
3 CB - OFFSET AREA V START CB - Offset Acquiring Area V-Start Position 500 0 - 1000 If not used: use Y's value
4 CR - OFFSET AREA H START CR - Offset Acquiring Area H-Start Position 925 0 - 1000 If not used: use Y's value