-72-
Electrical Adjustment
GROUP NO. ITEM FUNCTION RANGE INITIAL VALUE NOTE
130 75 ohm Terminate / Analog filter
0 TERM_1
(1) 75 ohm terminate On / Off (0: Off, 1: On)
(2)
Analog filter On/Off (0: Off, 1: On) on Input board side
0 / 1 0
1 TEMR_2 Analog filter On/Off (0: Off, 1: On) on Main Board side 0 / 1 0
131 DVI Equalizer Boost Setting
0 CH0 Boost Data 0 ~ 7 2
1 CH1 Boost Data 0 ~ 7 2
2 CH2 Boost Data 0 ~ 7 2
140 Fan Output Level * Fan Driving Voltage Adj.
0 Fan A Min 0 ~ 255 210
1 Fan A Max 0 ~ 255 48
2 Fan B Min 0 ~ 255 159
3 Fan B Max 0 ~ 255 36
4 Fan C Min 0 ~ 255 169
5 Fan C Max 0 ~ 255 48
6 Fan D1 Min 0 ~ 255 196
7 Fan D1 Max 0 ~ 255 34
8 Fan D2 Min 0 ~ 255 193
9 Fan D2 Max 0 ~ 255 31
10 Fan E Min 0 ~ 255 218
11 Fan E Max 0 ~ 255 38
141 Fan Option
0 Fan Output Level 0 : Max / 1: Factory / 2 : Auto / 3 : Min / 99: Menu 0 ~ 3, 99 1 (Shipment:99)
1 Fan Cooling Mode 0: Default, 1: FAN_C _MAX Fixed 0 ~ 1 0
160 Pressure Sensor Calibration
0 Press Offset -1023 ~ 1023 0
1 Press Calib Effective Diff 0 ~ 1023 120
2 Press Sensor Calibration Error Log
0: Executed OK
10: Out of Range at Minmum
20: Out of Range at Maxmum
99: Calibration Not Executed
- 99
170 Flow Sensor
0 Flow Sensor Calibration
Flow Sensor Offset Calibration
Execute auto-calibration when the value is set to 1
0 ~ 1 0 * Filter Calibration Adj.
1 Flow Sensor Offset Minimum Flow Sensor Minimum Offset Value 0 ~ 1023 0
2 Flow Sensor Offset Maximum Flow Sensor Maximum Offset Value 0 ~ 1023 0
3 Flow Sensor Calibration Error Log
Auto-calibration Error Log
0: No Error
10: Unstabled at Minimum
11: Out of Range at Minimum
20: Unstabled at Maximum
21: Out of Range at Maximum
- -
4 Clog Check Enable
Clogged Detection with Flow Sensor
0: Disable, 1: Enable
0 ~ 1 0 (Shipment: 1)
171 Flow Sensor
0 Ideal Flow Data Read only -
1 Flow Difference Data Read only -
2 Clog Detect Flow Difference Data Read only -
3 Warn Detect Flow Difference Data Read only -
4 Press Add Data Read only -
5 Filter Scroll Timer (Filter used time) Read only -
175 Filter
0 Take up Bend Remove the filter bending 0 ~ 1 0
1 Take up Bend Remove the filter bending 0 ~ 1 0
2 Take up Times Filter Scroll Remaining Times (Read only) 9
3 Take up Time Reset
Reset the Filter Scroll Times
Reset when the value reaches 10
0 ~ 10 0
4 Scroll Counter Reset Time Reset Times of Scroll Counter 0 ~ 255 0
176 Filter Display
0 Filter Icon display 0 : disable / 1 : Enable 0 / 1 1
177 Filter Timer Reset
0 Filter Counter Reset Times User Menu Filter Counter Reset Times 0 ~ 255 0
180 DDC Setting
0 HDCP EDID Data Setting 0 : EDID Data for DVI / 1 : EDID Data for HDCP 0 / 1 1
1 DDC Data Automatic Renewal 0 : Enable / 1 : Disable 0 / 1 0
190 Panel Life Test Pattern Display
0 Panel Life Test Pattern 0 : White 73% Raster Step Pattern Display / 1 : Normal 0 / 1 1
280 CXA7007
0 G SIG Center 0 ~ 63 32
1 B SIG Center 0 ~ 63 32