-47-
Electrical Adjustments
Group
/
Item
Item Name Function Initial Range Note
10 Close Limit Dimmer 0 728 0-1023
11 Close Limit Dimmer 1 714 0-1023
12 Close Limit Dimmer 2 684 0-1023
13 Close Limit Dimmer 3 654 0-1023
14 Close Limit Dimmer 4 624 0-1023
15 Close Limit Dimmer 5 594 0-1023
16 Close Limit Dimmer 6 564 0-1023
17 Close Limit Dimmer 7 534 0-1023
18 Close Limit Dimmer 8 504 0-1023
19 Close Limit Dimmer 9 474 0-1023
20 Close Limit Dimmer 10 444 0-1023
21 Close Limit Dimmer 11 414 0-1023
22 Close Limit Dimmer 12 384 0-1023
23 Close Limit Dimmer 13 354 0-1023
24 Close Limit Dimmer 14 324 0-1023
25 Close Limit Dimmer 15 294 0-1023
30 Update Interval 18/18 0-1023 (AV/PC)
Group
230
VBI Slice Level
0 Generic Initial Slicing Level PW190 register 0xE344 9 0-255
1
Generic High Level Threshold
PW190 register 0xE345 0 0-255
2
Generic Low Level Threshold
PW190 register 0xE346 0 0-255
3
Generic Minimum Low Level
PW190 register 0xE347 0 0-255
4 Generic Maximum High Level PW190 register 0xE348 255 0-255
Group
250
FAN Control
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
38 0 - 255
1 FAN1 MAX ADJUST (DAC) 233 0 - 255
2 FAN2 MIN ADJUST (DAC) 38 0 - 255
3 FAN2 MAX ADJUST (DAC) 230 0 - 255
4 FAN3 MIN ADJUST (DAC) 31 0 - 255
5 FAN3 MAX ADJUST (DAC) 214 0 - 255
6 Not used
7 Not used
Group
252
FAN Option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-3
0 0 - 5
1 SAFETY SWITCH For test purpose 0 0 - 6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100 0 - 255
4 FAN2 MANUAL VOLTAGE 100 0 - 255
5 FAN3 MANUAL VOLTAGE 100 0 - 255
6 Not used -
PLC-XK2200
Group
253
Fan Tem Error Setting (Memorized)
Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 Temp A Warning (High) 45 51 48 50 -
1 Temp B Warning (High) 58 63 58 63 -
2 Temp C Warning (High) 63 68 63 68 -
3 Temp B-A Warning(High) 100 100 100 100 -
4 Temp C-A Warning(High) 100 100 100 100 -
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
45 50 46/47 48/49 30-100
On1/On2
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
58 63 58 63 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
63 68 63 68 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
50 51 46 47/48 30-100
On1/On2
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
63 63 58 58 30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
67 67 62 62 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100 100 100 100 0-100