-9-
1. Receive the 16-step gray scale video signal with
Input 3 [VIDEO] mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “TP531” (+) and
chassis ground (-).
4. Select group no. “6”, item no. “11” and change data
value to adjust the pedestal level and black level to be
the same level.
5. Connect an oscilloscope to test point “TP501” (+) and
chassis ground (-).
6. Select item no. “12” and change data value to adjust
the pedestal level and black level to be the same
level.
7. Connect an oscilloscope to test point “TP561” (+) and
chassis ground (-).
8. Select item no. “10 and change data value to adjust
the pedestal level and black level to be the same
level.
1. Receive the 16-step gray scale computer signal with
Input 1 [COMPUTER] mode.
2. Enter the service mode.
3. Project only green light component to the screen.
4. Select group no. “5”, item no. “11” and change data
value to obtain the minimum flicker on the screen.
5. Project only blue light component to the screen.
6. Select item no. “12” and change data value to obtain
the minimum flicker on the screen.
7. Project only red light component to the screen.
8. Select item no. “10” and change data value to obtain
the minimum flicker on the screen.
A/D Offset adjustment
Common Center adjustment
[PC WHITE BALANCE ADJUSTMENT]
1. Receive the 16-step gray scale computer signal with
Input 1 [COMPUTER] mode.
2. Enter the service mode.
3. Select group no. “4”, item no. “7” (Red) or “8”(Blue),
and change data values respectively to make a prop-
er white balance.
[AV WHITE BALANCE ADJUSTMENT]
4. Receive the 16-step gray scale video signal with
Input 3 [VIDEO] mode.
5. Enter the service mode.
6. Select group no. “4”, item no. “7” (Red) or “8”(Blue),
and change data values respectively to make a prop-
er white balance.
Confirm that the same white balance is obtained in
video and computer input.
White Balance adjustment
If you find the color shading on the screen, please
adjust the white uniformity by using the proper comput-
er and “Color Shading Correction” software supplied
separately. The software can be ordered as follows;
COLOR SHADING CORRECTION SOFTWARE
Ser
vice Parts No. 645 051 2308
NOTE ON WHITE UNIFORMITY
ADJUSTMENT
1. Receive the 16-step gray scale video signal with Input
3 [VIDEO] mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “TP531”(+)
and chassis ground (-).
4. Select group no. “4”, item no. “4” and set data value
to “600”, and then decrease data to adjust waveform
“a” to be minimum amplitude.
5. Connect an oscilloscope to test point “TP501”(+)
and chassis ground (-).
6. Select item no. “5” and set data value to “600”, and
then decrease data to adjust waveform “a” to be mini-
mum amplitude.
7. Connect an oscilloscope to test point “TP561”(+)
and chassis ground (-).
8. Select item no. “3” and set data value to “580”, and
then decrease data to adjust waveform “a” to be mini-
mum amplitude.