-41-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
43 Lamp PWM PresPcA 2 0-255
44 Lamp PWM PresPcB 3 0-255
45 Lamp PWM PrefHAv50Hz 5000 0-65535
46 Lamp PWM PrefHAv60Hz 5000 0-65535
47 Lamp PWM PrefHUnlock 5000 0-65535
50 Lamp Replacement Display Lamp Warning Display On / Off 1 0 - 1 1: On, 0: Off
51 Filter Warning Display Filter Warning Display On / Off 1 0 - 1 1: On, 0: Off
52 Lamp Counter reset Times Reset Times of Lamp Counter 0 0 - 255 Read only
54
Factory Default Execute
Times
Reset times of Fanctory Default 0 0 - 255 Read only
55 Motor Disable Motors Disable 0 0 - 1 0: On, 1: Off
56 Menu Position Move menu (X asis) 0 0 - 1024
57 Menu Position Move menu (Y asis) 0 0 - 1024
58 Lamp Go Out 0 0 - 1
59 Souce Search Enable Source Search Enable 1 0 - 1
60 Lanuage Default setting
0:English(Default) 1:Janpanese
0 0 - 1 Set the default language
Group
201
Option (signal)
0 FrameLock Option 1 0 - 1
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
47Hz (Vfreq) ~ Panel frequency of
input signal
2 Field Sense Invert Enable 0 0 - 1
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
Value
1: Enable - Used Reversed FLDINV
Setting Value
3
4 Sub Image Enable 1 0 - 1
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
1:Enable (Service Adjustment
Enable)
6 Zoom Accelerator Enable 0 0 - 1
0:Zoom Accelerator OFF,
1:Zoom Accelerator ON
No last memory
7 DZoom Reset by Keystone 0 0 - 1
0:Enable (Normal), 1:Disable (Dzoo
is not cancelled even if Keystone is
cancelled)
No last memory
8 Stability Count Count Value of V-missing 5 0 - 255
9
Sensivity for Signal Lost
(HSYNC)
Only used this value for No Signal
Judgement(Hz)
350 0 - 65535
10
Sensivity for Signal Lost
(VSYNC)
Only used this value for No Signal
Judgement(Line)
3 0 - 255
11 Keystone Filter Center Value Reference Value 16 0 - 30
Group
202
Option (MCI model only)
0 Memory Viewer OSD
Memory Viewer OSD Display (1: Yes,
0: No)
1 0 - 1
Group
210
LampContorl
0 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for Dimmer:
Dim Level 1 at the less than the
Value
7 0 - 255
1 DIMMER_CTRL_LEVEL2
Luminance Level 2 Data for Dimmer:
Dim Level 2 at the less than the
Value
14 0 - 255
2 DIMMER_CTRL_LEVEL3
Luminance Level 3 Data for Dimmer:
Dim Level 3 at the less than the
Value
21 0 - 255
3 DIMMER_CTRL_LEVEL4
Luminance Level 4 Data for Dimmer:
Dim Level 4 at the less than the
Value
28 0 - 255
4 DIMMER_CTRL_LEVEL5
Luminance Level 5 Data for Dimmer:
Dim Level 5 at the less than the
Value
35 0 - 255
5 DIMMER_CTRL_LEVEL6
Luminance Level 6 Data for Dimmer:
Dim Level 6 at the less than the
Value
42 0 - 255
6 DIMMER_CTRL_LEVEL7
Luminance Level 7 Data for Dimmer:
Dim Level 7 at the less than the
Value
49 0 - 255
7 DIMMER_CTRL_LEVEL8
Luminance Level 8 Data for Dimmer:
Dim Level 8 at the less than the
Value
56 0 - 255