-29-
Electrical Adjustments
Group
No. Item Function Range Initial Value
90 Operation History
0 OPERATION_HISTORY_1 Operation history in last operation 0~32767 0
~
49 OPERATION_HISTORY_50 Operation history last 50th operation 0~32767 0
50 OPERATION_HISTORY Reset It resets the history when the value is changed to 10. 0 ~ 10 0
91 Projector Failure History
* See "Power Falure Error His
-
tory"
0 Warning Log 1 Latest Failure log 0 ~ 32767 0
~
49 Warning Log 50 50th Failure log 0 ~ 32767 0
50 Warning Log Reset It resets the Log when the value is changed to 10. 0 ~ 10 0
112 Lamp Config
0 Lamp Config Change Lamp life selection (Step : 500h) 1000 ~8000 2000/1500
113 Lamp Reset Counter (Read only)
0 Lamp Reset Counter Reset times of the Lamp time counter 0 ~127 0
115 Kamp Go Out
0 Lamp Go Out 0: Disable / 1: Enable 0 / 1 0
116 Lamp Replace Display
0 Display when Lamp Replace time 0: Disable / 1: Enable 0 / 1 0
120 RC KEY Disable
1 RC KEY Front/Rear Disable 0:Enable / 1:Front RC Disable / 2:Rear RC Disable / 3:RC KEY All Disable 0 ~ 3 0
130 75 ohm terminated
0 TERM_1 Input1(D SUB) terminated (0: OFF / 1: ON) 0 / 1 0
1 TERM_2 Input2(BNC) terminated (0: OFF / 1: ON) 0 / 1 0
140 Fan Control
0 Fan A Max (DAC) 0 ~ 255
1 Fan A Min (DAC) 0 ~ 255
2 Fan B Max (DAC) 0 ~ 255
3 Fan B Min (DAC) 0 ~ 255
4 Fan C Max (DAC) 0 ~ 255
5 Fan C Min (DAC) 0 ~ 255
6 Fan D Max (DAC) 0 ~ 255
7 Fan D Min (DAC) 0 ~ 255
8 Fan E Max (DAC) 0 ~ 255
9 Fan E Min (DAC) 0 ~ 255
10 Fan F Max (DAC) 0 ~ 255
11 Fan F Min (DAC) 0 ~ 255
141 Fan Optiion
0 Hi-Land SW 0:Normal Mode1: High-land Mode (Fan max speed continuously) 0 ~ 1 0
1 Not used Not used --
142 Fan Temp Error Setting Read only 300W
0 Temp A Warning Temp A to judge the temp error (x10) 0 ~ 1000 460
1 Temp B Warning Temp B to judge the temp error (x10) 0 ~ 1000 800
2 Temp C Warning Temp C to judge the temp error (x10) 300 ~ 1000 590
3 Temp B-A Warning Temp B-A to judge the temp error (x10) 0 ~ 1000 500
4 Temp C-A Warning Temp C-A to judge the temp error (x10) 0 ~ 1000 270
143 Fan Manual Control for factory exam
144 Fan Table Settingl for factory exam
145 Fan Offset Setting for factory exam
146 Fan Start Setting for factory exam
147 Fan Air pressure Setting for factory exam
148 Fan Ceiling Setting for factory exam