Electrical Adjustments
Service Adjustment Data Table
These initial values are the reference data written from the
CPU ROM to memory IC when replaced new memory IC. The
adjustment items indicated with
are required to readjust fol-
lowing to the “Electrical adjustments”. Other items should be
used with the initial data value.
Group
No. Item Function Range Initial Value
0 Thermal Monitor Read only
0 LM76(Temp) A Monitor Sensor A for External IC1691 - -
1 LM76(Temp) B Monitor Sensor B for Lamp IC1816 - -
2 LM76(Temp) C Monitor Sensor C for Panel IC1814 - -
1 Atmosphere Monitor Read only
0 MPXA4114A(Pressure) Monitor Atmosphere sensor - -
1 MPXA4114A(Pressure) Monitor Atmosphere sensor [unit: mmHg] - -
2 MPXA4114A(Pressure) Monitor Atmosphere sensor [unit:hpa] - -
5 FAN A Monitor (PBS) Current voltage of Fan (0.01V unit)
FAN B Monitor (Lamp-IN) Current voltage of Fan (0.01V unit)
- -
FAN C Monitor (Lamp-Front) Current voltage of Fan (0.01V unit)
- -
FAN D Monitor (Power) Current voltage of Fan (0.01V unit) - -
FAN E Monitor (Panel) Current voltage of Fan (0.01V unit)
- -
FAN F Monitor (Exhust) Current voltage of Fan (0.01V unit) - -
10 RS232C Setting * Do not change setting when using LAN card
0 Reset Disable PJ-Net Reset (0:Enable / 1:Disable) 0 / 1 0
11 PJ-Net Setting
0 LAN Card Switch LAN (0: Disable / 1: Enable) 0 / 1 0
20 Logo prohibition
0 Logo prohibition Logo prohibition(0: Menu / 1: Forced) 0 / 1 0
30 Color Shading/Gamma
0 Color Shading Correction On/Off Color Shading Correction (0:Off / 1:On) 0 / 1 1 Not memorized
1 Gamma Correction On/Off Gamma Correction (0:Off / 1:On) 0 / 1 1 Not memorized
40 Dimmer Control
0 Dimmer Level 0:250 ~ 15:300W Effect only 300W 0 ~ 15 15
2 DIMMER CTRL LEVEL1 Bright level1 data: Bright level1 when less than the value 0 ~ 255 7
3 DIMMER CTRL LEVEL2 Bright level2 data: Bright level2 when less than the value 0 ~ 255 14
4 DIMMER CTRL LEVEL3 Bright level3 data: Bright level3 when less than the value 0 ~ 255 21
5 DIMMER CTRL LEVEL4 Bright level4 data: Bright level4 when less than the value 0 ~ 255 28
6 DIMMER CTRL LEVEL5 Bright level5 data: Bright level5 when less than the value 0 ~ 255 35
7 DIMMER CTRL LEVEL6 Bright level6 data: Bright level6 when less than the value 0 ~ 255 42
8 DIMMER CTRL LEVEL7 Bright level7 data: Bright level7 when less than the value 0 ~ 255 49
9 DIMMER CTRL LEVEL8 Bright level8 data: Bright level8 when less than the value 0 ~ 255 56
10 DIMMER CTRL LEVEL9 Bright level9 data: Bright level9 when less than the value 0 ~ 255 63
11 DIMMER CTRL LEVEL10 Bright level10 data: Bright level10 when less than the value 0 ~ 255 70
12 DIMMER CTRL LEVEL11 Bright level11 data: Bright level11 when less than the value 0 ~ 255 77
13 DIMMER CTRL LEVEL12 Bright level12 data: Bright level12 when less than the value 0 ~ 255 84
14 DIMMER CTRL LEVEL13 Bright level13 data: Bright level13 when less than the value 0 ~ 255 91
15 DIMMER CTRL LEVEL14 Bright level14 data: Bright level14 when less than the value 0 ~ 255 98
16 DIMMER CTRL LEVEL15 Bright level15 data: Bright level15 when less than the value 0 ~ 255 105
17 DIMMER AVE POINT Average point data for dimmer 1~16 4
50 Auto-Picture Control
0 Auto-Picture Control Forced OFF 0:follows to Menu, 1:Forced OFF 0 / 1 0
70 COOLING
0 COOLING_TIME Cooling time period after power off 10-120 90
1 Not used -1
80 Projector Use time
0 PJ Time Reset It resets the time when the value is changes to 10. 0 ~ 10 0