Sanyo PLV-80 - Optical Unit Top Removal

Sanyo PLV-80
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-16-
* Lens should be placed
as the flat surface side
comes to the holder
side.
Optical Parts Disassemblies
1 Remove 7 screws to take the Optical Unit Top off upward.
Optical Unit Top removal
1 Remove 2 hex screws A and take the Condenser Lens ass’y.
2 Release 4 hooks B to take the Lens off from the holder.
A
Fig.6-2
Fig.6-1
B
Holder
Condenser Lens
A
Condenser Lens disassembly
Condenser Lens