Does the temperature
switch operate?
If the temperature around FET
reaches 85 degrees, a PFC
circuit will be shut down.
Does the temperature switch
operate?
When the temperature around a
lamp driver reaches 85 degrees, unit
lamp ballast will be shut down and a
lamp monitor signal changes from L
to H.
Do the temperature switches operate?
Temperature switches are arranged near each lamp.
If a tem-
perature of lamp reaches an unusual temperature, the
temperature switch will operate.
The lamp ballast units shut down, then the projector
is turned off when the temperature switches operate.
■ Note :
The CPU does not check operation of temperature
switches. Therefore, the TEMPERATURE WARN-
ING indicator does not blink when the temperature
switches operate and the projector is shut down.
■ The CPU shuts down the projector
compulsorily.
CPU performs temperature check
around the LCD panel using tempera-
ture sensor IC2561 (B-side of assembly
main). If this temperature reaches 47
degrees, CPU will turn off a projector,
and will blink
TEMPERATURE WARN-
ING
indicator at intervals of 0.6 seconds.
■ The CPU controls Air flow.
CPU checks the temperature and
atmospheric pressure inside a pro-
jector. And CPU controls the drive
power of the cooling fans so that
the temperature inside the projec-
tor may be maintained to normal
temperature.
Temperature sensors location can be
seen “protections” on page 5.
Any of the projector models
are not equipped with the
PTH901.