Protections
This projector is equipped
with the following protec-
tions to operate in safety.
Fuse for circuit protection
MY6A
CAUTION
The fuse is safety significant part. For
continued safety, it should be used the
specified fuse as follows;
Fuse Part No. :
423 027 2602
TYPE T10AH250V FUSE
LITTLEFUSE INC.TYPE 215010
■ Protection equipment for lamp replacement :
The Lamp circuit (the lamp and the electrode of the lamp socket) of
this projector is not insulated from AC line, and it is “HOT”.
Therefore, an electric shock may be received when you replace the
lamp assembly. However, this projector is designed to protect you from
the accident. This switch(SW902) insulates a lamp circuit from AC
line when lamp cover is removed. (The lamp circuit is changed to
“COLD” by this switch.)
■ The note for the service personnel about the
repair of the projector :
Remember that the interlock switch is opened during dis-
assembling the cabinet. The projector can't be turned on.
(Some of the service personnel forget it often.) When you
want to turn on the projector without cabinet, press and
hold the lever of the interlock switch.
The fuse is located at the rear of a projector. (Refer to figure.)
When either the LAMP indicator or the READY indicator is
not illuminated, the fuse may be opened. Check the fuse as
following steps.
1. Remove the Cabinet top.
Refer to “Mechanical Disassemblies” on pages 9~10.
2. Remove the fuse from fuse holder.
(To install the fuse, take reversed step in the above.)
3. Check the fuse using a tester.
This caution label is located near the Fuse.
TYPE T10AH250V FUSE. (LITTLEFUSE INC TYPE 215010
)
CALIBRES A T10AH250V. (LITTLEFUSE INC TYPE 215010)
1AA6P4S2203--
Boss inside the lamp cover