2-1-4. Heat Pump Type (265 V)
Model Number
Heater class 3.00 kW STW0633H2 STW0933H2 STW1233H2
4.00 kW STW0634H2 STW0934H2 STW1234H2 STW1534H2
5.00 kW STW1235H2 STW1535H2
Voltage (V) 265
Performance HEAT PUMP
Cooling capacity BTU/h 7,100 9,000 12,000 14,000
(kW) (2.08) (2.64) (3.52) (4.1)
Heat pump capaciity BTU/h 6,400 8,100 10,800 13,300
(kW) (1.88) (2.37) (3.16) (3.9)
Air Flow....Hi CFM 315 315 410 410
(CMH) (535) (535) (697) (697)
Dehumidification Pints/h 2.3 2.8 3.8 3.8
Electrical Rating
Available voltage range V 239 to 291
Cooling Amperes A 2.4 3.0 4.2 5.7
Watts W 610 790 1,100 1,490
Power factor % 96 99 99 99
EER BTU/hW 11.6 11.4 10.9 9.4
Starting amperes A 13 15 24 31
Heat pump Amperes A 2.2 2.9 3.9 5.2
Watts W 570 740 1,020 1,350
COP W/W 3.3 3.2 3.1 2.9
Features
Controls / Temperature control Mechanical / Themostat
Control unit
Timer
Fan speeds 2
Airflow direction (Indoor) Horizontal Manual
Vertical
Air filter Washable
Air exhaust Yes
Compressor Rotary (Hermetic)
R22-Amount charged at shipment OZ 26.8 30.0 32.1 33.5
Refrigerant control Capillary Tube
Operation sound Indoor : Hi / Lo dB-A 44 / 42 47 / 45
Outdoor dB-A 60 61
Dimensions & Weight
Unit dimensions Height In 15-15/16
(Refer to page 11) Width In 41-1/8
Depth In 21-1/2
Package dimensions Height In 18-3/16
Width In 44-7/8
Depth In 24-7/8
Weight Net lbs 95 100 110 110
Shipping lbs 110 115 125 125
Shipping volume Cu Ft 11.7
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Electric Heating Specifications
Electric Heating
Model number STW0633C2 STW0634C2
STW0933C2 STW0934C2
STW1233C2 STW1234C2 STW1235C2
STW1534C2 STW1535C2
Heater class kW 3.00 4.00 5.00
Capacity BTU/h 10,200 13,600 17,000
Electrical rating Amperes A 11.4 15.2 19.0
Watts W 3,000 4,000 5,000
Recommended circuit protection A 15 20 30