8. MAINTENANCE
8 - 11
Alarm Status
Segment LED
Display
Alarm Code
ALM8,4,2,1
Abbreviation
Alarm
Name
Alarm
Clear
Contents
1010 FP
Main
power
supply
phase
loss
Possible Phase loss detected in 3-phase main
power supply input
Alarm code 0,1 indicates: when Func2/ bit7,6 =”0,0”, “0”= output open and “1”= output short.
Operating state when alarm occurred
POSSIBLE CAUSES
OPERATING STATE
1 2 3
When control power supply is turned on
When main power supply is turned on
During motor operation
Alarm occurred although specified single phase
power input
Corrective Measures
CAUSE CORRECTIVE MEASURES
1 Faulty input contact on one of the R, S, T
phases
Check and correct wiring.
2 Faulty amplifier internal circuit Replace servo amplifier
3 Servo amplifier is not specified for single
phase
Confirm model number and delivery specification of
servo amplifier. Replace with amplifier for single
phase, if necessary.
Change parameter for single phase Amplifier
(Mode4-page8 PSKD)