EasyManua.ls Logo

Sanyo SUPER BL PY - Position Signal Output

Sanyo SUPER BL PY
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9. SPECIFICATIONS
913
9.1.6 Position Signal Output
This section explains the position signal output specifications.
Chapter Contents Relevant Sensors
9.1.6.1 Pulse output Fig. 9-6 Wiring-saved incremental encoder INC-E
Request-signal unavailable absolute encoder ABS-E
Request-signal available absolute sensor ABS-R
Wiring-saved absolute sensor ABS-E.S1
9.1.6.2 Serial output
(When absolute encoder ABS-E
is used.)
Fig. 9-7-1
Fig. 9-7-2
Fig. 9-7-3
Request-signal unavailable absolute encoder ABS-E
9.1.6.3 Serial output
(When absolute sensor ABS-R
is used.)
Fig. 9-8-1
Fig. 9-8.2
Fig. 9-8-3
Request-signal available absolute sensor ABS-R
9.1.6.4 Serial output (When wiring-saved
absolute sensor ABS-E.S1 is
used.)
Fig. 9-9-1
Fig. 9-9-2
Fig. 9-9-3
Wiring-saved absolute sensor ABS-E.S1
9.1.6.1 Pulse Output
CN1-3 to 8 output 90° phase difference 2-phase pulses (A- and B-phases) and the home position (C-phase)
pulse .
Not specified for about 1s after the control power is turned on.
90°
t
Approx.
1s
Not specified
Not specified
Not specified
Control power
supply
A
-phase
B-phase
C-phase
<Forward revolution>
B-phase leads A-phase by a phase angle of 90°.

Table of Contents