50 ACU-280 SATEL
5. Press any numeric key to define whether the detector is to send out alarm to other
ASD-250 detectors ( – no, – yes).
6. Press .
AVD-100 (AVD-200)
For the magnetic contact:
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Define whether the detector is to be always active by pressing any number key ( – no,
– yes).
4. Press .
5. When the reed switch settings are displayed, press (these settings are irrelevant).
For the shock detector:
1. Enter a digit from the 1 to 8 range to define sensitivity (1 – minimum; 8 – maximum).
2. Press .
3. When the settings regarding the number of shocks are displayed, press (these settings
are irrelevant).
ASP-100 (ASP-200)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Use the and keys to select the type of acoustic signaling (see table 9).
4. Press .
5. Use the and keys to define the maximum duration of signaling.
6. Press .
ASP-205 (ASP-215)
You can program two different ways of signaling:
• having selected the first of the zones – signaling triggered by the first output controlling the
siren,
• having selected the second of the zones – signaling triggered by the second output
controlling the siren.
Configuration is similar for both zones, however, the step in which the rules of device
presence control are defined is skipped for the second zone.
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Use the and keys to define how the acoustic signaling will work (
– disabled; 1, 2
or 3 – type of acoustic signaling – see table 10).
4. Press .
5. Use the and keys to define the maximum duration of signaling.
6. Press .
7. Define whether the optical signaling is to be enabled ( – no, – yes).
8. Press .
ASW-100 (ASW-200)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .