62 ACU-280 SATEL
to 140 ms, every 20 ms; above 140 ms, only some values are available: 400 ms,
500 ms, 700 ms, etc. every 200 ms).
The EN 50131-3 standard requires that zones must react to signals lasting more than
400 ms. Therefore, select 400 ms when programming sensitivity of the alarm zones.
ACX-220 – hardwired zone / output expander. For each position taken up by the expander,
you can configure:
Wiring type – select NC; NO; EOL; 2EOL/NC or 2EOL/NO.
Reaction time – define how long the zone must remain activated so that this can be
registered by the controller. You can program from 20 to 5000 ms (in the range of 20 ms
to 140 ms, every 20 ms; above 140 ms, only some values are available: 400 ms,
500 ms, 700 ms, etc. every 200 ms).
The EN 50131-3 standard requires that zones must react to signals lasting more than
400 ms. Therefore, select 400 ms when programming sensitivity of the alarm zones.
ADD-200 – wireless outdoor dusk and temperature detector. For the dusk sensor, you can
configure:
Sensitivity – select a number from a range of 1 to 16 (1 – minimum; 16 – maximum).
For the temperature sensor, you can configure:
Temperature threshold – select the threshold type:
H – high (when the temperature rises above the defined value, alarm will be generated),
L – low (when the temperature drops below the defined value, alarm will be generated).
Temperature – enter a number from a range of -30 to +70 (with 0.5 accuracy) to define
temperature.
Tolerance – enter a number from a range of 0.5 to 10 (with 0.5 accuracy) to define
tolerance.
AGD-200 – wireless glass-break detector. You can configure:
Sensitivity – select low, medium or high.
AMD-202 – wireless magnetic contact with input for roller shutter detector. For the roller
shutter input, you can configure:
Pulses number – select the number of pulses after which the roller shutter input will
generate alarm. You can select a number from a range of 1 to 8.
Counting time – select the time period during which the defined number of pulses must
occur for the roller shutter input to generate alarm. You can select 30 seconds,
120 seconds, 240 seconds or “---“ (unlimited time).
AOCD-260 – wireless outdoor dual technology curtain detector. You can configure:
PIR sensitivity – select a number from a range of 1 to 4 (1 – minimum; 4 – maximum).
MW sensitivity – select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
AOD-210 – wireless outdoor dual technology motion detector. You can configure:
PIR sensitivity – select a number from a range of 1 to 4 (1 – minimum; 4 – maximum).
MW sensitivity – select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
Dusk det. sensitivity – select a number from a range of 1 to 4 (1 – minimum;
4 - maximum).
APD-200 – wireless passive infrared detector. You can configure:
Sensitivity – select low, medium or high.
APD-200 Pet – wireless passive infrared detector with pet immunity up to 20 kg. You can
configure:
Sensitivity – select low, medium or high.