SATEL ACU-280 63
APMD-250 – wireless dual technology detector. You can configure:
PIR sensitivity – select a number from a range of 1 to 4 (1 – minimum; 4 – maximum).
MW sensitivity – select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
Test mode – select how the detector should work in the test mode:
PIR & MW – alarm after motion is detected by both sensors,
PIR – alarm after motion is detected by PIR sensor,
MW – alarm after motion is detected by microwave sensor.
ARD-200 – wireless reorientation detector. You can configure:
Sensitivity – select a number from a range of 1 to 16 (1 – minimum; 16 – maximum).
ART-200 – wireless radiator thermostat. You can configure:
Comfortable temp. – enter a number from a range of 5 to 30 (with accuracy to 0.5) to
define the temperature for the “Comfortable temperature” operating mode.
Economic temp. – enter a number from a range of 5 to 30 (with accuracy to 0.5) to define
the temperature for the “Economic temperature” operating mode.
Temp. measurement – select the sensor that will provide data on temperature:
internal – thermostat sensor,
[Device name] – temperature sensor of an ABAX 2 system device.
Head keys disabled – enable this option if you want to disable the thermostat keys.
ASD-250 – wireless smoke detector. You can configure:
Alarm from other detectors – enable the option if the detector is to signal alarm from
other ASD-250 detectors.
Alarm propagation – enable the option if the detector is to send alarm to other ASD-250
detectors.
ATD-200 – wireless temperature detector. For both positions occupied by the detector,
you can configure:
Temperature threshold – select the threshold type:
H – high (when the temperature rises above the defined value, alarm will be generated),
L – low (when the temperature drops below the defined value, alarm will be generated).
Temperature – enter a number from a range of -30 to +70 (with 0.5 accuracy) to define
temperature.
Tolerance – enter a number from a range of 0.5 to 10 (with 0.5 accuracy) to define
tolerance.
ATX-230 – hardwired zone expander: NC and roller shutter. For the roller shutter input, you
can configure:
Pulses number – select the number of pulses after which the roller shutter input will
generate alarm. You can select a number from a range of 1 to 8.
Counting time – select the time period during which the defined number of pulses must
occur for the roller shutter input to generate alarm. You can select 30 seconds,
120 seconds, 240 seconds or “---“ (unlimited time).
AVD-200 – wireless shock detector and magnetic contact. For the shock detector you can
configure:
Sensitivity – select a number from a range of 1 to 8 (1 – minimum; 8 – maximum).
ASP-200 – wireless outdoor siren. You can configure:
Signaling time – select the maximum time of signaling: 1 minute, 3 minutes, 6 minutes or
9 minutes.
Sound – select the type of acoustic signaling: 1 (sound type 1), 2 (sound type 2), 3 (sound
type 3) or 4 (sound type 4) – see Table 13.