cdef - hold down for 3 sec.
to GOTO selected partition
g
- hold down for 3 sec. to
activate alarm log viewing
j - hold down for 3 sec. to
activate/deactivate CHIME signaling
[
*
] - hold down for 3 sec. to restore basic
partition (GOTO) or to activate
FIRE ALARM
CODE+[
*
] - User Functions:
[CODE][
*
][1] - user access code change
[CODE][
*
][2] - user (code) add
[CODE][
*
][3] - user (code) erase
[CODE][
*
][4] - zone bypass
[CODE][
*
][5] - silent arming
[CODE][
*
][6] - time setting
[CODE][
*
][7] - MONO switch outputs activate
[CODE][
*
][8] - BI switch outputs activate
[CODE][
*
][9] - power supply reset
[CODE][
*
][0] - DOWNLOADING start
b
- hold down for 3 sec. to
activate AUXILIARY ALARM
[#]-hold down for 3 sec. to activate PANIC ALARM
CODE+[#] – arm/disarm partition, clear alarm
ALARM – blinking signals an
alarm in current partition
TROUBLE – indicates detection of
system trouble – check by holding
down key
i
for 3 sec.
ARMED
on – partition armed,
blinking – exit time countdown
i - hold down for 3 sec. to activate
current trouble condition display
TROUBLE DISPLAY:
1,2,3 - Output 1,2,3 trouble
4 - 230V AC loss
5 - Low battery
6 - Keypad supply fail
7 - Time not set
8 - Printer trouble
9 - Telephone line loss
10 - Problem with transmission to
monitoring station
11 - Telephone line trouble
12 - Output 4 trouble
all off - System memory fault
LEDs 1÷12 (zones state)
ON
- zone violated
OFF
- zone OK
fast blinking
- zone activated alarm
on , short off every 2 sec.
- zone tamper violated
flashing every 2 sec.
- zone tamper activated alarm
slow blinking
- zone bypassed
h - hold down for 3 sec. to activate
trouble log viewing.
TROUBLE DISPLAY: LED ON =
1,2,3 - Output 1,2,3 trouble
4 - 230VAC loss
5 - Battery trouble
6 - Keypad power supply trouble
7 - Time not set
8 - Printer trouble
9 - Telephone line loss
10 - Problem with transmission to
monitoring station
11 - not used
12 - Output 4 trouble