22 PERFECTA-T SATEL
Enter the user menu and press in turn to run 3.SIGNAL LEVEL function. The signal
level information will be presented as a percentage. You can scroll the list using the
and keys.
6.16.4 Starting the test transmission
The 4.TEST EVENT function makes it possible to test the communication with monitoring
stations. Enter the user menu and press in turn to run 4.TEST EVENT function. A
“Manual transmission test” event will be saved to the control panel memory. The event code
will be sent to the monitoring station.
6.16.5 Checking the firmware version of devices in system
Using the 8.FW VERSIONS function, you can check the firmware version of devices included in
the alarm system:
control panel,
expansion modules,
wireless devices PERFECTA-T 32-WRL.
Enter the user menu and press in turn to run 8.FW VERSIONS function. Information
on the control panel firmware version will be displayed. To scroll the list of devices, use the
and keys.
6.17 Replacing battery in wireless keypad
If you want to replace the battery in wireless keypad, you must run the REPLACE BATTERY
function first. This will prevent the tamper alarm from being triggered when you open the
keypad enclosure.
1. Enter the user menu.
2. Keep pressing the key until the cursor indicates the REPLACE BATTERY function.
3. Press .
4. After the “SELECT...” message appears, use the or key to find on the list the
wireless keypad in which you want to replace the battery.
5. Press . Tamper alarms from the selected keypad will be blocked for 3 minutes.
During that time you can replace the battery.
6.18 Service access
If the alarm system is to comply with the EN 50131 standard requirements for
Grade 2, the service access should be limited.
The SERVICE ACCESS function allows you to define the rules of access to the system by the
person using the service code (installer/service technician). These rules apply to getting
access to the alarm system by using the keypad or PERFECTA SOFT program.
Starting the function will display the list of options. To scroll the list, use the and
keys.
Active – if this option is enabled, the installer/service technician has access to the alarm
system i.e.:
– after entering the service code, it is possible to enter the service mode and run some
functions available in the user menu,
– it is possible to configure the alarm system by using the PERFECTA SOFT program.
Partition 1 – if this option is enabled, the installer/service technician can operate the partition
1 (arm / disarm it, clear alarm, bypass / unbypass zones) and edit the users (he cannot