Page 9-22
Section 9. Optional Accessories
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
Real Time Clock Chip Installation
MAIN PCB BOARD
REMOVE THE EEPROM CHIP
MARK ON CHIP IDENTIFIES
PIN 1. BE SURE TO ALIGN
CHIP CORRECTLY IN CHIP
BLOCK SOCKET USING THE
“U” SHAPED NOTCH AS
REFERENCE
INSTALL THE
TIMEKEEPER CHIP IN
VACATED LOCATION
PIN 1
PIN 1
Figs. 9-27